Standardized guidelines for the interpretation of dobutamine echocardiography reduce interinstitutional variance in interpretation

被引:92
作者
Hoffmann, R
Lethen, H
Marwick, T
Rambaldi, R
Fioretti, P
Pingitore, A
Picano, E
Buck, T
Erbel, R
Flachskampf, FA
Hanrath, P
机构
[1] Klinikum RWTH Aachen, Med Clin 1, D-52057 Aachen, Germany
[2] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[3] Thorax Ctr Rotterdam, Rotterdam, Netherlands
[4] Univ Pisa, Pisa, Italy
[5] Univ GHS, Essen, Germany
关键词
D O I
10.1016/S0002-9149(98)00697-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Subjective interpretation of dobutamine echocardiograms provides only moderate interinstitutional observer agreement if nonunified data acquisition and assessment criteria are applied. The present study was undertaken to evaluate parameters associated with low interinstitutional observer agreement in the interpretation of dobutamine echocardiograms and to analyze whether standardized interpretation criteria improve interinstitutional observer agreement. One hundred fifty dobutamine echocardiograms (dobutamine up to 40 mu g/kg/min body weight and atropine up to 1 mg) were evaluated at 5 centers. Clinical, procedural, and echocardiographic parameters were included in the analysis of variables with significant impact on interinstitutional agreement Standardized interpretative criteria were established, and 90 dobutamine echocardiograms were reanalyzed by 3 observers using a standardized Image display. Multivariate analysis demonstrated low image quality (odds ratio [OR] 0.19, 95% confidence interval [CI] 0.08 to 0.45, p = 0.0002), low severity of induced wall motion abnormality (OR 0.17, 95% CI 0.07 to 0.40, p <0.0001), and a low peak rate-pressure product (OR 0.93, 95% CI 0.43 to 2.27, p = 0.0382) to result in a low interinstitutional agreement. Standardization of image display in cine loop format and of dobutamine stress echo interpretation criteria resulted in improvement in test result categorization as normal or abnormal, with a kappa value of 0.50, compared with 0.39 using the original subjective interpretation. In conclusion, image quality, the severity of induced wall motion abnormalities, and the obtained rate-pressure product have a significant impact on the interpretation homogeneity of dobutamine echocardiograms. Standardization of image display in cine loop format and of reading criteria results in improved interinstitutional agreement in interpretation of stress echocardiograms. (C) 1998 by Excerpta Medica, Inc.
引用
收藏
页码:1520 / 1524
页数:5
相关论文
共 23 条
  • [11] HAUSNEROVA E, 1994, CIRCULATION, V90, P391
  • [12] Analysis of interinstitutional observer agreement in interpretation of dobutamine stress echocardiograms
    Hoffmann, R
    Lethen, H
    Marwick, T
    Arnese, M
    Fioretti, P
    Pingitore, A
    Picano, E
    Buck, T
    Erbel, R
    Flachskampf, FA
    Hanrath, P
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (02) : 330 - 336
  • [13] Quantitative evaluation of the segmental left ventricular response to dobutamine stress by tissue Doppler echocardiography
    Katz, WE
    Gulati, VK
    Mahler, CM
    Gorcsan, J
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (08) : 1036 - 1042
  • [14] ACCURACY OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY IN DETECTING CORONARY-ARTERY DISEASE
    MARCOVITZ, PA
    ARMSTRONG, WF
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (16) : 1269 - 1273
  • [15] SELECTION OF THE OPTIMAL NONEXERCISE STRESS FOR THE EVALUATION OF ISCHEMIC REGIONAL MYOCARDIAL DYSFUNCTION AND MALPERFUSION - COMPARISON OF DOBUTAMINE AND ADENOSINE USING ECHOCARDIOGRAPHY AND TC-99M-MIBI SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY
    MARWICK, T
    WILLEMART, B
    DHONDT, AM
    BAUDHUIN, T
    WIJNS, W
    DETRY, JM
    MELIN, J
    [J]. CIRCULATION, 1993, 87 (02) : 345 - 354
  • [16] Segmental analysis of color kinesis images - New method for quantification of the magnitude and timing of endocardial motion during left ventricular systole and diastole
    MorAvi, V
    Vignon, P
    Koch, R
    Weinert, L
    Garcia, MJ
    Spencer, KT
    Lang, RM
    [J]. CIRCULATION, 1997, 95 (08) : 2082 - 2097
  • [17] REPRODUCIBILITY OF TWO-DIMENSIONAL EXERCISE ECHOCARDIOGRAPHY
    OBERMAN, A
    FAN, PH
    NANDA, NC
    LEE, JY
    HUSTER, WJ
    SULENTIC, JA
    STOREY, OF
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (04) : 923 - 928
  • [18] STRESS ECHOCARDIOGRAPHY AND THE HUMAN FACTOR - THE IMPORTANCE OF BEING EXPERT
    PICANO, E
    LATTANZI, F
    ORLANDINI, A
    MARINI, C
    LABBATE, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (03) : 666 - 669
  • [19] IMPROVED ENDOCARDIAL BORDER RESOLUTION DURING DOBUTAMINE STRESS ECHOCARDIOGRAPHY WITH INTRAVENOUS SONICATED DEXTROSE ALBUMIN
    PORTER, TR
    XIE, F
    KRICSFELD, A
    CHIOU, A
    DABESTANI, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (06) : 1440 - 1443
  • [20] SEGALL H N, 1960, Can Med Assoc J, V82, P2