Experimental testing of a DEXA-derived curved beam model of the proximal femur

被引:20
作者
Beck, TJ
Mourtada, FA
Ruff, CB
Scott, WW
Kao, G
机构
[1] Johns Hopkins Univ, Dept Radiol & Radiol Sci, Baltimore, MD USA
[2] Johns Hopkins Univ, Dept Cell Biol, Baltimore, MD USA
[3] Johns Hopkins Univ, Dept Anat, Baltimore, MD USA
[4] Johns Hopkins Univ, Sch Med, Dept Orthopaed Surg, Baltimore, MD USA
[5] Johns Hopkins Univ, Sch Hyg & Publ Hlth, Dept Environm Hlth Sci, Baltimore, MD USA
关键词
D O I
10.1002/jor.1100160317
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was designed to test whether, using curved beam theory, a structural model of the proximal femur derived from two-dimensional dual energy x-ray absorptiometry could be used To predict femoral strength in an experimental simulation of a fall on the greater trochanter. A set of 22 fresh cadaveric femoral specimens were scanned with use of two-dimensional dual energy x-ray absorptiometry and then were tested to failure in a materials testing system, under three-point loading, with the ground impact vector aligned within the plane and along the bisector of the femoral neck-shaft angle. Failure locations generally corresponded to stress peak locations predicted by the curved beam model. Predicted failure loads correlated well with measured failure loads for femoral neck fractures (r = 0.89; percent SE of estimate = 23%) and somewhat less well for intertrochanteric fractures (r = 0.83; percent SE of estimate = 29%). Overall predictions for failure load calculated from the maximum stress peak value over both locations corresponded to measured failure loads with an r value of 0.91 (percent SE of estimate = 21%). This kind of structural approach to the analysis of data for hip bone mass has the potential to provide mechanistic interpretations of the statistical associations frequently shown between conventional bone mineral measures and either hip fracture risk in vivo or bone strength in vitro.
引用
收藏
页码:394 / 398
页数:5
相关论文
共 18 条
[11]   NON-INVASIVE MEASUREMENT OF LONG-BONE CROSS-SECTIONAL MOMENT OF INERTIA BY PHOTON-ABSORPTIOMETRY [J].
MARTIN, RB ;
BURR, DB .
JOURNAL OF BIOMECHANICS, 1984, 17 (03) :195-201
[12]   AGE-RELATED-CHANGES IN THE TENSILE PROPERTIES OF CORTICAL BONE - THE RELATIVE IMPORTANCE OF CHANGES IN POROSITY, MINERALIZATION, AND MICROSTRUCTURE [J].
MCCALDEN, RW ;
MCGEOUGH, JA ;
BARKER, MB ;
COURTBROWN, CM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (08) :1193-1205
[13]   Curved beam model of the proximal femur for estimating stress using dual-energy X-ray absorptiometry derived structural geometry [J].
Mourtada, FA ;
Beck, TJ ;
Hauser, DL ;
Ruff, CB ;
Bao, G .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (03) :483-492
[14]  
MYERS ER, 1992, T ORTHOP RES SOC, V17, P115
[15]  
PHILLIPS JR, 1975, BIOMED ENG, V10, P367
[16]   ELASTIC AND ULTIMATE PROPERTIES OF COMPACT BONE TISSUE [J].
REILLY, DT ;
BURSTEIN, AH .
JOURNAL OF BIOMECHANICS, 1975, 8 (06) :393-&
[17]  
Weber T., 1992, ADV BIOENG, V22, P111
[18]  
[No title captured]