Glucose biosensors based on platinum nanoparticles-deposited carbon nanotubes in sol-gel chitosan/silica hybrid

被引:140
作者
Kang, Xinhuang [1 ,2 ]
Mai, Zhibin [1 ]
Zou, Xiaoyong [1 ]
Cai, Peixiang [1 ]
Mo, Jinyuan [1 ]
机构
[1] Sun Yat Sen Univ, Sch Chem & Chem Engn, Guangzhou 510275, Peoples R China
[2] Guangdong Ocean Univ, Coll Sci, Zhanjiang 524088, Peoples R China
关键词
glucose; biosensors; carbon nanotubes; platinum nanoparticles; sol-gel; chitosan;
D O I
10.1016/j.talanta.2007.07.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new strategy for fabricating a sensitivity-enhanced glucose biosensor was presented, based on multi-walled carbon nanotubes (CNT), Pt nanoparticles (PtNP) and sol-gel of chitosan (CS)/silica organic-inorganic hybrid composite. PtNP-CS solution was synthesized through the reduction Of PtCl62- by NaBH4 at room temperature. Benefited from the amino groups of CS, a stable PtNP gel was obtained, and a CNT-PtNP-CS solution was prepared by dispersing CNT functionalized with carboxylic groups in PtNP-CS solution. The CS/silica hybrid sol-gel was produced by mixing methyltrimethoxysilane (MTOS) with the CNT-PtNP-CS solution. Then, with the immobilization of glucose oxidase (GOD) into the sol-gel, the glucose biosensor of GOD-CNT-PtNP-CS-MTOS-GCE was fabricated. The properties of resulting glucose biosensor were measured by electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). In phosphate buffer solutions (PBS, pH 6.8), nearly interference free determination of glucose was realized at low applied potential of 0.1 V, with a wide linear range of 1.2 x 10(-6) to 6.0 x 10(-3) M, low detection limit of 3.0 x 10(-7) M, high sensitivity of 2.08 mu A mM(-1), and a fast response time (within 5 s). The results showed that the biosensor provided the high synergistic electrocatalytic action, and exhibited good reproducibility, long-term stability. Subsequently, the novel biosensor was applied for the determination of glucose in human serum sample, and good recovery was obtained (in the range of 95-104%). (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:879 / 886
页数:8
相关论文
共 45 条
[1]  
Bard A. J., 2001, ELECTROCHEMICAL METH, P44
[2]   Amperometric glucose biosensor based on electrodeposition of platinum nanoparticles onto covalently immobilized carbon nanotube electrode [J].
Chu, Xia ;
Duan, Daxue ;
Shen, Guoli ;
Yu, Ruqin .
TALANTA, 2007, 71 (05) :2040-2047
[3]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[4]   Gold nanoparticles: Assembly, supramolecular chemistry, quantum-size-related properties, and applications toward biology, catalysis, and nanotechnology [J].
Daniel, MC ;
Astruc, D .
CHEMICAL REVIEWS, 2004, 104 (01) :293-346
[5]   Polypyrrole/copper hexacyanoferrate hybrid as redox mediator for glucose biosensors [J].
Fiorito, PA ;
Brett, CMA ;
de Torresi, SIC .
TALANTA, 2006, 69 (02) :403-408
[6]   Bioencapsulation within synthetic polymers (Part 1): sol-gel encapsulated biologicals [J].
Gill, I ;
Ballesteros, A .
TRENDS IN BIOTECHNOLOGY, 2000, 18 (07) :282-296
[7]   Electrochemical biosensing platforms using platinum nanoparticles and carbon nanotubes [J].
Hrapovic, S ;
Liu, YL ;
Male, KB ;
Luong, JHT .
ANALYTICAL CHEMISTRY, 2004, 76 (04) :1083-1088
[8]   Preparation and characterization of metal-chitosan nanocomposites [J].
Huang, HZ ;
Yuan, Q ;
Yang, XR .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2004, 39 (1-2) :31-37
[9]  
IKARIYAMA Y, 1987, ANAL LETT, V20, P1791
[10]   Amperometric biosensors based on redox polymer-carbon nanotube-enzyme composites [J].
Joshi, PP ;
Merchant, SA ;
Wang, YD ;
Schmidtke, DW .
ANALYTICAL CHEMISTRY, 2005, 77 (10) :3183-3188