Image compression in digital mammography: Effects on computerized detection of subtle microcalcifications

被引:30
作者
Chan, HP
Lo, SCB
Niklason, LT
Ikeda, DM
Lam, KL
机构
[1] GEORGETOWN UNIV, DEPT RADIOL, WASHINGTON, DC 20057 USA
[2] UNIV MICHIGAN, DEPT RADIAT ONCOL, ANN ARBOR, MI 48109 USA
关键词
mammography; digital; microcalcifications; image compression; computer-aided diagnosis; DIAGNOSTIC-ACCURACY; AIDED DETECTION; WAVELET TRANSFORM; RADIOGRAPHY; METHODOLOGY;
D O I
10.1118/1.597871
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our previous receiver operating characteristic (ROC) study indicated that the detection accuracy of microcalcifications by radiologists is significantly reduced if mammograms are digitized at 0.1 mmx0.1 mm. Our recent study also showed that detection accuracy by computer decreases as the pixel size increases from 0.035 mmx0.035 mm. It is evident that very large matrix sizes have to be used for digitizing mammograms in order to preserve the information in the image. Efficient compression techniques will be needed to facilitate communication and archiving of digital mammograms. In this study, we evaluated two compression techniques: full frame discrete cosine transform (DCT) with entropy coding and Laplacian pyramid hierarchical coding (LPHC). The dependence of their efficiency on the compression parameters was investigated. The techniques were compared in terms of the trade-off between the bit rate and the detection accuracy of subtle microcalcifications by an automated detection algorithm. The mean-square errors in the reconstructed images were determined and the visual quality of the error images was examined. It was found that with the LPHC method, the highest compression ratio achieved without a significant degradation in the detectability was 3.6:1. The full frame DCT method with entropy coding provided a higher compression efficiency of 9.6:1 at comparable detection accuracy. The mean-square errors did not correlate with the detection accuracy of the microcalcifications. This study demonstrated the importance of determining the quality of the decompressed images by the specific requirements of the task for which the decompressed images are to be used. Further investigation is needed for selection of optimal compression technique for digital mammograms. (C) 1996 American Association of Physicists in Medicine.
引用
收藏
页码:1325 / 1336
页数:12
相关论文
共 31 条
[31]   TECHNOLOGY-TRANSFER IN DIGITAL MAMMOGRAPHY - REPORT OF THE JOINT NATIONAL-CANCER-INSTITUTE NATIONAL-AERONAUTICS-AND-SPACE-ADMINISTRATION WORKSHOP OF MAY 19-20 [J].
WINFIELD, D ;
SILBIGER, M ;
BROWN, GS ;
CLARKE, L ;
DWYER, S ;
YAFFE, M ;
SHTERN, F .
INVESTIGATIVE RADIOLOGY, 1994, 29 (04) :507-515