Combined PET/CT with iodine-124 in diagnosis of spread metastatic thyroid carcinoma:: a case report

被引:15
作者
Freudenberg, LS
Antoch, G
Görges, R
Knust, J
Pink, R
Jentzen, W
Debatin, JF
Brandau, W
Bockisch, A
Stattaus, J
机构
[1] Univ Essen Gesamthsch, Clin & Policlin Nucl Med, D-45122 Essen, Germany
[2] Univ Essen Gesamthsch, Dept Radiol, D-45122 Essen, Germany
关键词
thyroid cancer; staging; PET; PET/CT; iodine-124; dual modality;
D O I
10.1007/s00330-003-1884-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Iodine-124 positron emission tomography (PET) is a useful 3D imaging technique for diagnosis and management of thyroid diseases. The difficulty in interpretation of the PET scans with highly selective tracers, such as iodine-124, is the lack of identifiable anatomical structures, so an accurate anatomical localization of foci presenting abnormal uptake is problematic. Consequently, a combined PET/CT scanner can resolve these difficulties by co-registering PET and CT data in a single session allowing a correlation of functional and morphologic imaging. A case is presented where iodine-124 produced by a clinical cyclotron and FDG were used to acquire images with a combined PET/CT scanner for clinical staging. On the basis of the PET/CT exams the treatment of the patient was modified.
引用
收藏
页码:L19 / L23
页数:5
相关论文
共 23 条
[1]  
Alnafisi NS, 2000, J NUCL MED, V41, P1010
[2]   Comparison of F-18 FDG to I-123 and I-131 scans in thyroid carcinoma [J].
Bakheet, SM ;
Powe, JE ;
Hammami, MM ;
Ahmed, M .
CLINICAL NUCLEAR MEDICINE, 1997, 22 (06) :438-439
[3]  
Beyer T, 2000, J NUCL MED, V41, P1369
[4]  
Chung JK, 1999, J NUCL MED, V40, P986
[5]   Thyroid volume measurement in thyrotoxic patients: comparison between ultrasonography and iodine-124 positron emission tomography [J].
Crawford, DC ;
Flower, MA ;
Pratt, BE ;
Hill, C ;
Zweit, J ;
McCready, R ;
Harmer, CL .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (12) :1470-1478
[6]  
Erdi Yusuf E., 1999, Clin Positron Imaging, V2, P41, DOI 10.1016/S1095-0397(99)00004-7
[7]   Evaluation of dosimetry of radioiodine therapy in benign and malignant thyroid disorders by means of iodine-124 and PET [J].
Eschmann, SM ;
Reischl, G ;
Bilger, K ;
Kupferschläger, J ;
Thelen, MH ;
Dohmen, BM ;
Besenfelder, H ;
Bares, R .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (06) :760-767
[8]  
FLOWER MA, 1994, EUR J NUCL MED, V21, P531
[9]   TOMOGRAPHIC IMAGING OF THE HUMAN THYROID USING I-124 [J].
FREY, P ;
TOWNSEND, D ;
FLATTET, A ;
DEGAUTARD, R ;
WIDGREN, S ;
JEAVONS, A ;
CHRISTIN, A ;
SMITH, A ;
LONG, A ;
DONATH, A .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1986, 63 (04) :918-927
[10]  
FREY P, 1985, EUR J NUCL MED, V10, P472