Direct comparison of skin physiology in children and adults with bioengineering methods

被引:56
作者
Fluhr, JW [1 ]
Pfisterer, S [1 ]
Gloor, M [1 ]
机构
[1] Klinikum Karlsruhe, Dept Dermatol, D-76133 Karlsruhe, Germany
关键词
D O I
10.1046/j.1525-1470.2000.01815.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
The aim of the study was to investigate whether the physiologic skin parameters of transepidermal water loss (TEWL), stratum corneum hydration (capacitance and conductance), dynamic stratum corneum hydration parameters (hygroscopicity and water-holding capacity), skin color (a* and L* axes; chromameter), cutaneous blood perfusion [laser Doppler flowmetry (LDF)], and pH value differ between a sample of 44 children [C] (average age 3.5 years) and a directly comparable sample of 44 adults (their parents) [P] (average age 34.6 years). The results can be described as follows: TEWL C: 6.2 g/m(2)/h, P: 5.4 g/m(2)/h; stratum corneum hydration, capacitance C: 75.4 AU, P: 76.1 AU; conductance C: 27.1 muS, P: 19.2 muS; hygroscopicity C: 129.0 AU, P: 132.7 AU; water-holding capacity: C: 127.7 AU, P: 127.6 AU; redness (a*) C: 7.31, P: 8.21; lightness (L*) C: 67.63, P: 66.36; LDF (%) C: 24.6, P: 18.7; pH value C: 4.91, P: 5.07. In comparison to the skin of the adult sample we investigated (the parents of the 44 children), the skin of the small child can be characterized in the following way: it has a significantly lower hygroscopicity, a lighter (higher L* values) and less red color (lower a* values), and an increased cutaneous blood perfusion (LDF).
引用
收藏
页码:436 / 439
页数:4
相关论文
共 18 条
[1]  
Berardesca E, 1997, Skin Res Technol, V3, P126, DOI 10.1111/j.1600-0846.1997.tb00174.x
[2]  
BERARDESCA E, 1995, BIOENGINEERING SKIN
[3]   GUIDELINES FOR MEASUREMENT OF CUTANEOUS BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY - A REPORT FROM THE STANDARDIZATION GROUP OF THE EUROPEAN-SOCIETY-OF-CONTACT-DERMATITIS [J].
BIRCHER, A ;
DEBOER, EM ;
AGNER, T ;
WAHLBERG, JE ;
SERUP, J .
CONTACT DERMATITIS, 1994, 30 (02) :65-72
[4]  
BLICHMANN CW, 1988, ACTA DERM-VENEREOL, V68, P284
[5]  
DIEPGEN TL, 1989, ACTA DERM-VENER S, V144, P33
[6]  
Elsner P., 1998, SKIN BIOENGINEERING
[7]  
ELSNER P, 1994, BIOENGINEERING SKIN
[8]  
Fluhr J W, 1998, Z HAUTKRANKHEITEN, V73, P210
[9]   Comparative study of five instruments measuring stratum corneurn hydration (Comeometer CM 820 and CM 825, Skicon 200, Nova DPM 9003, DermaLab). Part I. In vitro [J].
Fluhr, Joachim W. ;
Gloor, Max ;
Lazzerini, Sabrina ;
Kleesz, Peter ;
Grieshaber, Romano ;
Berardesca, Enzo .
SKIN RESEARCH AND TECHNOLOGY, 1999, 5 (03) :161-170
[10]   Comparative study of five instruments measuring stratum corneum hydration (Corneometer CM 820 and CM 825, Skicon 200, Nova DPM 9003, DermaLab). Part II. In vivo [J].
Fluhr, Joachim W. ;
Gloor, Max ;
Lazzerini, Sabrina ;
Kleesz, Peter ;
Grieshaber, Romano ;
Berardesca, Enzo .
SKIN RESEARCH AND TECHNOLOGY, 1999, 5 (03) :171-178