Minimizing artifacts caused by metallic implants at MR imaging: Experimental and clinical studies

被引:142
作者
Suh, JS
Jeong, EK
Shin, KH
Cho, JH
Na, JB
Kim, DH
Han, CD
机构
[1] Yonsei Univ, Coll Med, Dept Diagnost Radiol, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Res Inst Radiol Sci, Seoul, South Korea
[3] Yonsei Univ, Coll Med, Dept Orthoped Surg, Seoul, South Korea
关键词
D O I
10.2214/ajr.171.5.9798849
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to investigate the effect of metallic implant positioning on MR imaging artifacts, to determine the optimal imaging conditions for minimizing artifacts, and to show the usefulness of artifact-minimizing methods in imaging of the knee. MATERIALS AND METHODS. Using MR images of experimental phantoms (titanium alloy and stainless steel screws), we compared the magnitude of metal-induced artifacts for various pulse sequences, different imaging parameters for the fast spin-echo sequence, and different imaging parameters for several incremental angles between the long axis of the screw and the direction of the main magnetic field. In clinical MR imaging of knees with metallic implants (n = 19), we assessed geometric distortion of anatomic structures to compare the influence of different pulse sequences (n = 19), frequency-encoding directions (n = 7), and knee positions (n = 15). RESULTS, Titanium alloy screws consistently produced smaller artifacts than did stainless steel screws. In experimental MR studies, artifacts were reduced with fast spin-echo sequences, with a screw orientation as closely parallel to the main magnetic field as possible, and, particularly, with smaller voxels that correlated positively with artifact size (R-2 = .88, p < .01). In clinical MR studies, fast spin-echo MR imaging obscured articular structures less than did spin-echo imaging (8/19 patients), In particular, the anterior-posterior frequency-encoding direction (3/7 patients) and the flexion position of the knee (5/15 patients) were effective in reducing artifacts. CONCLUSION. MR artifacts can be minimized by optimally positioning in the magnet subjects with metallic implants and by choosing fast spin-echo sequences with an anterior-posterior frequency-encoding direction and the smallest voxel size.
引用
收藏
页码:1207 / 1213
页数:7
相关论文
共 23 条
[11]  
Ludeke K M, 1985, Magn Reson Imaging, V3, P329, DOI 10.1016/0730-725X(85)90397-2
[12]   THE EFFECT OF MAGNETIC-RESONANCE IMAGING ON METAL SPINE IMPLANTS [J].
LYONS, CJ ;
BETZ, RR ;
MESGARZADEH, M ;
REVESZ, G ;
BONAKDARPOUR, A ;
CLANCY, M .
SPINE, 1989, 14 (07) :670-672
[13]   Optimizing imaging parameters for MR evaluation of the spine with titanium pedicle screws [J].
Petersilge, CA ;
Lewin, JS ;
Duerk, JL ;
Yoo, JU ;
Ghaneyem, AJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) :1213-1218
[14]   SUSCEPTIBILITY ARTIFACTS IN SPIN-ECHO AND GRADIENT-ECHO IMAGING [J].
POSSE, S ;
AUE, WP .
JOURNAL OF MAGNETIC RESONANCE, 1990, 88 (03) :473-492
[15]  
RUPP R, 1993, SPINE, V18, P379
[16]   The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds [J].
Schenck, JF .
MEDICAL PHYSICS, 1996, 23 (06) :815-850
[17]   MR IMAGING AND METALLIC IMPLANTS FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION - ASSESSMENT OF FERROMAGNETISM AND ARTIFACT [J].
SHELLOCK, FG ;
MINK, JH ;
CURTIN, S ;
FRIEDMAN, MJ .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02) :225-228
[18]   MR IMAGING OF METALLIC IMPLANTS AND MATERIALS - A COMPILATION OF THE LITERATURE [J].
SHELLOCK, FG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (04) :811-814
[19]   HIGH-FIELD-STRENGTH MR IMAGING AND METALLIC BIOMEDICAL IMPLANTS - AN EXVIVO EVALUATION OF DEFLECTION FORCES [J].
SHELLOCK, FG ;
CRUES, JV .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (02) :389-392
[20]   MR PROCEDURES AND BIOMEDICAL IMPLANTS, MATERIALS, AND DEVICES - 1993 UPDATE [J].
SHELLOCK, FG ;
MORISOLI, S ;
KANAL, E .
RADIOLOGY, 1993, 189 (02) :587-599