Physical activity assessment: A review of methods

被引:124
作者
Melanson, EL [1 ]
Freedson, PS [1 ]
机构
[1] UNIV MASSACHUSETTS, DEPT EXERCISE SCI, AMHERST, MA 01003 USA
关键词
physical activity; physical fitness; epidemiology; exercise; accelerometer; energy expenditure;
D O I
10.1080/10408399609527732
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
In order to determine the actual threshold level of habitual physical activity necessary to obtain protective effects against degenerative diseases, valid, reliable, nonreactive, and precise instruments are needed. Because regular, low-intensity exercise provides prophylactic effects, the ability to distinguish activity patterns should be a primary consideration when choosing an instrument to assess activity in the field. Although self-report methods in the form of questionnaires are the instruments of choice when large populations are to be assessed, they are somewhat limited in their objectivity. The doubly labeled water (DLW) technique is a highly accurate and objective technique for assessing total daily energy expenditure that should be utilized more as a criterion measure for validating questionnaires that assess energy expenditure. However, the DLW technique remains too costly to be considered practical for large-scale studies. Supplementing questionnaires with a personal interview does elicit more detailed data, but activity monitors provide a more objective measure of activity that can be used as an adjunct to questionnaires. Several models of activity monitors are capable of collecting and storing data for many days, weeks, or even months. More importantly, the internal real-time clocks of these monitors allow the discrimination of activity patterns. Future studies should combine the use of these monitors with a suitable questionnaire.
引用
收藏
页码:385 / 396
页数:12
相关论文
共 90 条
[71]   PHYSICAL-ACTIVITY ASSESSMENT METHODOLOGY IN THE 5-CITY PROJECT [J].
SALLIS, JF ;
HASKELL, WL ;
WOOD, PD ;
FORTMANN, SP ;
ROGERS, T ;
BLAIR, SN ;
PAFFENBARGER, RS .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1985, 121 (01) :91-106
[72]   USE OF PEDOMETER AND ACTOMETER IN STUDYING DAILY PHYSICAL-ACTIVITY IN MAN .2. VALIDITY OF PEDOMETER AND ACTOMETER MEASURING DAILY PHYSICAL-ACTIVITY [J].
SARIS, WHM ;
BINKHORST, RA .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1977, 37 (03) :229-235
[73]  
SARIS WHM, 1985, ACTA PAEDIATR SCAND, P37
[74]   USE OF PEDOMETER AND ACTOMETER IN STUDYING DAILY PHYSICAL-ACTIVITY IN MAN .1. RELIABILITY OF PEDOMETER AND ACTOMETER [J].
SARIS, WHM ;
BINKHORST, RA .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1977, 37 (03) :219-228
[75]   ENERGY-EXPENDITURE BY DOUBLY LABELED WATER - VALIDATION IN HUMANS AND PROPOSED CALCULATION [J].
SCHOELLER, DA ;
RAVUSSIN, E ;
SCHUTZ, Y ;
ACHESON, KJ ;
BAERTSCHI, P ;
JEQUIER, E .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 250 (05) :R823-R830
[76]   MEASUREMENT OF ENERGY-EXPENDITURE IN HUMANS BY DOUBLY LABELED WATER METHOD [J].
SCHOELLER, DA ;
VANSANTEN, E .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 53 (04) :955-959
[78]  
SCHULMAN JL, 1959, AM J MENT DEF, V64, P455
[79]  
SERVAIS S B, 1984, Journal of Clinical Engineering, V9, P159
[80]   INCIDENCE OF CORONARY HEART DISEASE IN A POPULATION INSURED FOR MEDICAL CARE (HIP) - MYOCARDIAL INFARCTION, ANGINA PECTORIS, AND POSSIBLE MYOCARDIAL INFARCTION [J].
SHAPIRO, S ;
WEINBLAT.E ;
FRANK, CW ;
SAGER, RV .
AMERICAN JOURNAL OF PUBLIC HEALTH AND THE NATIONS HEALTH, 1969, 59 (6P2S) :1-&