A composite amperometric tyrosinase biosensor for the determination of the additive propyl gallate in foodstuffs

被引:24
作者
Morales, MD
González, MC
Reviejo, AJ
Pingarrón, JM
机构
[1] Univ Complutense Madrid, Fac Chem, Dept Analyt Chem, E-28040 Madrid, Spain
[2] Univ Alcala De Henares, Fac Chem, Dept Analyt Chem, Madrid 28871, Spain
关键词
propyl gallate; composite electrochemical biosensor; tyrosinase; aqueous and predominantly nonaqueous media;
D O I
10.1016/j.microc.2004.10.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of a graphite-Teflon composite amperometric tyrosinase biosensor for the determination of the food additive propyl gallate (PG) in different types of foodstuffs is reported. The enzyme reaction involves the catalytic oxidation of PG to the corresponding o-quinone, and the electrochemical reduction of this o-quinone was employed to monitor the enzyme reaction. Depending on the nature of the food sample analysed and on the presence of other phenolic antioxidants in these samples, aqueous buffer solutions or predominantly nonaqueous acetonitrile-Tris buffer mixtures were employed as working media. Experimental conditions such as the aqueous solution percentage in the predominantly nonaqueous medium, pH, and the potential to be applied were optimised. Control charts constructed showed a useful lifetime for the biosensor of 40 days when working in phosphate buffer of pH 6.5, and of 50 days in 80:20 acetonitrile-Tris buffer (pH 7.4) mixture. The limits of detection obtained for PG in these media were 9.0 X 10(-7) and 1.1 X 10(-6) mol L-1, respectively. The composite bioelectrode also performed well in the flow-injection mode. PG was determined in dehydrated broth bars using the phosphate buffer solution of pH 6.5 as working medium. However, PG was determined in spiked olive oil in the working medium formed by the 80:20 acetonitrile-Tris buffer mixture, because a liquid-liquid extraction step was carried out. Comparison of the results with those obtained by applying reference methods showed that no significant differences existed at a significance level of 0.05. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 29 条
[1]  
AOAC, 1999, OFF METH AN AOAC INT
[2]  
Aparicio A, 2000, HRC-J HIGH RES CHROM, V23, P324
[3]  
BELITZ HD, 1997, QUIMICA ALIMENTOS, P261
[4]  
BUDAVARI S, 1989, MERCK INDEX, P1248
[5]   Development of a bienzymic graphite-Teflon composite electrode for the determination of hypoxanthine in fish [J].
Cayuela, G ;
Peña, N ;
Reviejo, AJ ;
Pingarrón, JM .
ANALYST, 1998, 123 (02) :371-377
[6]   Graphite-Teflon composite bienzyme amperometric biosensors for monitoring of alcohols [J].
de Prada, AGV ;
Peña, N ;
Mena, ML ;
Reviejo, AJ ;
Pingarrón, JM .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (10) :1279-1288
[7]   Graphite-teflon-peroxidase composite electrodes. Application to the direct determination of glucose in musts and wines [J].
del Cerro, MA ;
Cayuela, G ;
Reviejo, AJ ;
Pingarron, JM ;
Wang, J .
ELECTROANALYSIS, 1997, 9 (14) :1113-1119
[8]  
Diego E, 1998, ELECTROANAL, V10, P33, DOI 10.1002/(SICI)1521-4109(199801)10:1<33::AID-ELAN33>3.0.CO
[9]  
2-W
[10]   Chiral analysis of amino acids using electrochemical composite bienzyme biosensors [J].
Domínguez, R ;
Serra, B ;
Reviejo, AJ ;
Pingarrón, JM .
ANALYTICAL BIOCHEMISTRY, 2001, 298 (02) :275-282