Computational study of the band broadening in two-dimensional etched packed bed columns for on-chip high-performance liquid chromatography

被引:36
作者
Gzil, P [1 ]
De Smet, J [1 ]
Vervoort, N [1 ]
Verelst, H [1 ]
Baron, GV [1 ]
Desmet, G [1 ]
机构
[1] Free Univ Brussels, Dept Chem Engn, B-1050 Brussels, Belgium
关键词
band broadening; computational fluid dynamics; packed columns; etched columns; mathematical modelling; computer simulation;
D O I
10.1016/j.chroma.2003.12.038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The chromatographic performance of several straightforward two-dimensional etched packed bed column lay-outs (equilaterally staggered arrays of, respectively, circular, hexagonal, and diamond-like pillars) has been compared using commercial computational fluid dynamics software. In all cases, the bed porosity was kept at epsilon = 0.4 and a retained component with zone capacity ratio k" = 2 was considered. Exploring the use of six different possible characteristic dimensions to bring the Van Deemter plots of the three different considered particle shapes into agreement, none of them yielded a perfect agreement. Using the pillar volume-based equivalent cylinder diameter (d(eq)) as the characteristic dimension, the diamond-like pillars yielded a significantly smaller h(min) value than the cylinders and the hexagons (h(min) congruent to 0.74 for the former versus h(min) congruent to 0.83 for the two latter). Including the flow resistance into the analysis, it was found that the "hydrodynamic" shape of the particles has an important influence on the separation impedance E. The more axially elongated diamond pillars yielded an E-min number as small E-min = 180 (for a retained component with k" = 2), i.e. about 40% smaller than the cylinders and the hexagons (E-min = 300-330). The obtained h(min) and E-min values are also significantly smaller than the values often cited for the best possible packed bed HPLC columns. We believe this is a consequence of the assumed perfect homogeneity of the etched structures, and hence hints at the potential benefits of perfectly ordered chromatographic columns, as was already inferred by Knox [J. Chromatogr. A 831 (1999) 3; 960 (2002) 7] and He et al. [Anal. Chem. 70 (1998) 3790]. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:53 / 62
页数:10
相关论文
共 19 条
[1]  
[Anonymous], 1965, DYNAMICS CHROMATOGRA
[2]   Computer simulations of electrokinetic injection techniques in microfluidic devices [J].
Ermakov, SV ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 2000, 72 (15) :3512-3517
[3]   Computational fluid dynamics simulations yielding guidelines for the ideal internal structure of monolithic liquid chromatography columns [J].
Gzil, P ;
Baron, GV ;
Desmet, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 991 (02) :169-188
[4]   Fabrication of nanocolumns for liquid chromatography [J].
He, B ;
Tait, N ;
Regnier, F .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3790-3797
[5]  
Kaviany M., 1995, MECH ENG SERIES
[6]   Band dispersion in chromatography -: a new view of A-term dispersion [J].
Knox, JH .
JOURNAL OF CHROMATOGRAPHY A, 1999, 831 (01) :3-15
[8]   Band dispersion in chromatography - a universal expression for the contribution from the mobile zone [J].
Knox, JH .
JOURNAL OF CHROMATOGRAPHY A, 2002, 960 (1-2) :7-18
[9]   Chromatographic performance of monolithic and particulate stationary phases - Hydrodynamics and adsorption capacity [J].
Leinweber, FC ;
Tallarek, U .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1006 (1-2) :207-228
[10]   Characterization of silica-based monoliths with bimodal pore size distribution [J].
Leinweber, FC ;
Lubda, D ;
Cabrera, K ;
Tallarek, U .
ANALYTICAL CHEMISTRY, 2002, 74 (11) :2470-2477