Band dispersion in chromatography - a universal expression for the contribution from the mobile zone

被引:126
作者
Knox, JH [1 ]
机构
[1] Univ Edinburgh, Dept Chem, Edinburgh EH9 3JJ, Midlothian, Scotland
关键词
band dispersion; mobile zone; dispersion;
D O I
10.1016/S0021-9673(02)00240-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It is generally assumed that the dispersion which is covered by the C term of Van Deemter type equations arises from processes occurring in the static zone, while the dispersion covered by the A term arises from processes occurring in the mobile zone. It is also now widely accepted that the contribution to h, the reduced plate height, from mobile zone processes increases with a modest power of nu, the reduced flow velocity. A reassessment of data acquired since the 1960s suggests that this power falls with increasing velocity, but may be relatively high at reduced velocities, P, in the range 1-30. Data for a wide variety of materials over a wide range of P have been re-examined and are well fitted by an equation of the form: It = B/nu + {1/A + 1/(Dnu")}(-1) + Cnu. With C less than or equal to 0.02 in accordance with the theoretical value for slow equilibration in the static zone, n is found to be in the range 0.5-1.0 with the lower values applying to glass bead packings, and the higher values applying to porous spherical packing materials. The equation provides a decreasing power of velocity in the A term in agreement with experimental data. It is now clear that nearly all of the dispersion previously assigned to processes in the static zone actually occurs in the mobile zone. Accordingly, substantial improvements in column performance in LC may well be achieved by better packing of columns, or by designing structures such as monolithic beds and two dimensional designs on chips, which can provide more uniform structures than the beds of spherical particles widely used in current HPLC. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:7 / 18
页数:12
相关论文
共 25 条
[1]  
[Anonymous], 1965, DYNAMICS CHROMATOGRA
[2]   STANDARDIZATION OF TEST CONDITIONS FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS [J].
BRISTOW, PA ;
KNOX, JH .
CHROMATOGRAPHIA, 1977, 10 (06) :279-289
[3]   PERFORMANCE OF PACKINGS IN HIGH-SPEED LIQUID CHROMATOGRAPHY .2. ZIPAX - EFFECT OF PARTICLE-SIZE [J].
DONE, JN ;
KNOX, JH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1972, 10 (10) :606-&
[4]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[5]   NATURE OF GAS PHASE MASS TRANSFER IN GAS CHROMATOGRAPHY [J].
GIDDINGS, JC .
ANALYTICAL CHEMISTRY, 1962, 34 (10) :1186-&
[6]  
GOLAY MJE, 1958, GAS CHROMATOGRAPHY 1, P35
[7]  
HUBER JFK, 1969, J CHROMATOGR, V7, P86
[8]   PERFORMANCE OF PACKINGS IN HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) .1. POROUS AND SURFACE LAYERED SUPPORTS [J].
KENNEDY, GJ ;
KNOX, JH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1972, 10 (09) :549-&
[9]   POROUS SILICA MICROSPHERE COLUMN PACKINGS FOR HIGH-SPEED LIQUID-SOLID CHROMATOGRAPHY [J].
KIRKLAND, JJ .
JOURNAL OF CHROMATOGRAPHY, 1973, 83 (AUG29) :149-167