Ion-selective electrode for aluminum determination in pharmaceutical substances, tea leaves and water samples

被引:80
作者
Arvand, M. [1 ]
Asadollahzadeh, S. A. [1 ]
机构
[1] Guilan Univ, Fac Sci, Dept Chem, Rasht 0098, Iran
关键词
potentiometric Al(III) sensor; poly(vinyl chloride) membrane; non-aqueous media; isothermal temperature coefficient; sandwich method;
D O I
10.1016/j.talanta.2008.01.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel ion-selective PVC membrane sensor for Al(III) ions based on 6-(4-nitrophenyl)-2-phenyl-4-(thiophen-2-yl)-3,5-diaza-bicyclo[3.1.0]hex-2-ene (NTDH) as a new ionophore has been prepared and studied. The electrode exhibit a good response for aluminum ion over concentration range of 1.0 x 10(-6) to 1.0 X 10(-1) mol L-1 with a Nernstian slope of 19.6 +/- 0.4mV per decade and low detection limit of 6.3 x 10(-7) mol L-1. The best performance was obtained with membrane composition 30% poly(vinyl chloride), 62% acetophenone, 5% oleic acid, 3% ionophore and 2 ml tetrahydrofuran. NTDH-based electrode was suitable for aqueous solutions of pH 3. It has relatively fast response time (similar to 10s) and can be used at least for 3 months without any considerable divergence in potentials. The proposed membrane electrode revealed good selectivity for Al(III) ions over a wide variety of other cations. The standard electrode potentials were determined at different temperatures and used to calculate the isothermal coefficient of the electrode. The formation constant and stoichiometry ratio of ionophore-Al(III) complex were calculated at 25 degrees C by using segmented sandwich membrane method. It was used in non-aqueous solvents and also as indicator electrode in potentiometric determination of Al(III) ions in some real samples. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1046 / 1054
页数:9
相关论文
共 44 条
[1]   Aluminium(III)-selective electrode based on a newly synthesized tetradentate Schiff base [J].
Abbaspour, A ;
Esmaeilbeig, AR ;
Jarrahpour, AA ;
Khajeh, B ;
Kia, R .
TALANTA, 2002, 58 (02) :397-403
[2]   Tin(II)-selective membrane potentiometric sensor using a crown ether as neutral carrier [J].
Aghaie, H ;
Giahi, A ;
Monajjemi, M ;
Arvand, A ;
Nafissi, GH ;
Aghaie, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2005, 107 (02) :756-761
[3]  
AMMAN D, 1991, ANAL CHIM ACTA, V171, P1380
[4]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[5]  
[Anonymous], 1995, STANDARD METHODS EXA
[6]  
Antropov L. I., 1972, THEORETICAL ELECTROC
[7]   Novel thiocyanate-selective membrane sensor based on crown ether-cetyltrimethyl ammonium thiocyanate ion-pair as a suitable ionophore [J].
Arvand, M. ;
Zanjanchi, M. A. ;
Heydari, L. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) :301-308
[8]   Potentiometric membrane sensor based on 6-(4-nitrophenyl)-2,4-diphenyl-3,5-diaza-bicyclo[3.1.0] hex-2-ene for detection of Sn(II) in real samples [J].
Arvand, Majid ;
Moghimi, A. Majid ;
Afshari, Anoosheh ;
Mahmoodi, Nosratollah .
ANALYTICA CHIMICA ACTA, 2006, 579 (01) :102-108
[9]  
Babenikov V, 2005, J ANAL CHEM+, V60, P866
[10]  
Bakker E, 2004, TALANTA, V63, P3, DOI 10.1016/j.talanta.2003.10.006