Novel thiocyanate-selective membrane sensor based on crown ether-cetyltrimethyl ammonium thiocyanate ion-pair as a suitable ionophore

被引:34
作者
Arvand, M. [1 ]
Zanjanchi, M. A. [1 ]
Heydari, L. [1 ]
机构
[1] Guilan Univ, Fac Sci, Dept Chem, Rasht, Iran
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2007年 / 122卷 / 01期
关键词
thiocyanate; potentiometric sensor; ion-pair; coated graphite electrode; sequential determination;
D O I
10.1016/j.snb.2006.05.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric thiocyanate-selective sensor based on the use of crown ether-cetyltrimethyl ammonium-thiocyanate (CCT) as a neutral carrier for a thiocyanate-selective electrode is reported. The electrode was prepared by coating the membrane solution containing PVC, plasticizer, and carrier on the surface of graphite electrode. Influences of the membrane composition, pH, and possible interfering anions were investigated on the response properties of the electrode. The sensor exhibits significantly enhanced response toward thiocyanate ions over the concentration range 1 x 10(-6) to 1.0 x 10(-1) M with a lower detection limit of 0.03 mu gml(-1) and a slope of -57.6 mV decade(-1). Fast and stable response, good reproducibility, long-term stability, applicability over a wide pH range (3.8-9.2) are demonstrated. The sensor has a response time of <= 20s and can be used for at least 6 weeks without any considerable divergence in their potential response. The proposed electrode shows fairly good discrimination of thiocyanate from several inorganic and organic anions. The sensor is used for direct potentiometric measurements of thiocyanate ions over the concentration range 0.06-5800 mu g ml(-1) and for monitoring sequential titration of some metal ions (e.g. Ag+, Cu+, Pb2+) in binary and ternary mixtures. Sequential binding of these metal ions with SCN- ensures sharp stepwise fitration curves with consecutive end point breaks at the equivalent points. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:301 / 308
页数:8
相关论文
共 46 条
[1]   An ion-selective electrode for acetate based an a urea-functionalized porphyrin as a hydrogen-bonding ionophore [J].
Amemiya, S ;
Bühlmann, P ;
Umezawa, Y ;
Jagessar, RC ;
Burns, DH .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1049-1054
[2]   PVC-based cobalt and manganese phthalocyanine coated graphite electrodes for determination of thiocyanate [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYTICAL LETTERS, 1999, 32 (14) :2737-2750
[3]   A PTEV-based zeolite membrane potentiometric sensor for cesium ion [J].
Arvand-Barmchi, M ;
Mousavi, MF ;
Zanjanchi, MA ;
Shamsipur, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 96 (03) :560-564
[4]  
BART TY, 1992, J APPL CHEM-USSR+, V65, P446
[5]   PROBLEMS WITH THIOCYANATE AS AN INDEX OF SMOKING STATUS - A CRITICAL-REVIEW WITH SUGGESTIONS FOR IMPROVING THE USEFULNESS OF BIOCHEMICAL MEASURES IN SMOKING CESSATION RESEARCH [J].
BLISS, RE ;
OCONNELL, KA .
HEALTH PSYCHOLOGY, 1984, 3 (06) :563-581
[6]   MN(III) PORPHYRIN-BASED THIOCYANATE-SELECTIVE MEMBRANE ELECTRODES - CHARACTERIZATION AND APPLICATION IN FLOW-INJECTION DETERMINATION OF THIOCYANATE IN SALIVA [J].
BROWN, DV ;
CHANIOTAKIS, NA ;
LEE, IH ;
MA, SC ;
PARK, SB ;
MEYERHOFF, ME ;
NICK, RJ ;
GROVES, JT .
ELECTROANALYSIS, 1989, 1 (06) :477-484
[7]   ION SELECTIVE ELECTRODES, POTENTIOMETRY, AND POTENTIOMETRIC TITRATIONS [J].
BUCK, RP .
ANALYTICAL CHEMISTRY, 1972, 44 (05) :R270-+
[8]   Ion-selective electrodes for thiocyanate based on the dinuclear Zinc(II) complex of a Bis-N,O-bidentate Schiff base [J].
Bühlmann, P ;
Yahya, L ;
Enderes, R .
ELECTROANALYSIS, 2004, 16 (12) :973-978
[9]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[10]  
DAWANG D, 1985, ANALYST, V110, P635