Ion-selective electrodes for thiocyanate based on the dinuclear Zinc(II) complex of a Bis-N,O-bidentate Schiff base

被引:28
作者
Bühlmann, P [1 ]
Yahya, L [1 ]
Enderes, R [1 ]
机构
[1] Univ Minnesota, Dept Chem, Minneapolis, MN 55455 USA
关键词
thiocyanate; ion-selective electrode; Zinc(II) complex; sulfate; ionophore; solvent polymeric membrane;
D O I
10.1002/elan.200302937
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ion selective electrode based on the dinuclear complex formed by two zinc(II) ions and two molecules of the bis-N,O-bidentate Schiff base 2,2'-[methylenebis(4,1-phenylenenitrilomethylidyne)]bisphenol exhibits thiocyanate selectivity with a good discrimination of nitrite, nitrate, and azide. The selectivities of electrode membranes with various compositions indicate that this potentiometric selectivity is based on the formation of a 1:1 complex between the thiocyanate anion and the dinuclear ionophore. The 2:1 ratio of thiocyanate ions and the dinuclear ionophore that results from higher ratios of cationic sites and ionophore worsens the selectivity, suggesting that binding of a thiocyanate to both zinc(II) centers of the dinuclear ionophore is not favorable. Interestingly, the selectivity patterns of these electrodes differ radically from that of a highly sulfate selective electrode based on a compound reported previously to be the analogous mononuclear 1:1 complex of zinc(II) and the same Schiff base. It is suggested that the previously reported 1:1 complex with zinc(II) may indeed have been a polymer of the same elemental composition.
引用
收藏
页码:973 / 978
页数:6
相关论文
共 42 条
[1]   Thiocyanate-selective electrode based on unsymmetrical benzoN4 nickel(II) macrocyclic complexes [J].
Abbaspour, A ;
Kamyabi, MA ;
Esmaeilbeig, AR ;
Kia, R .
TALANTA, 2002, 57 (05) :859-867
[2]   Cationic or anionic sites?: Selectivity optimization of ion-selective electrodes based on charged ionophores [J].
Amemiya, S ;
Bühlmann, P ;
Pretsch, E ;
Rusterholz, B ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1618-1631
[3]   Hydrogen bond based recognition of nucleotides by neutral-carrier ion-selective electrodes [J].
Amemiya, S ;
Buhlmann, P ;
Tohda, K ;
Umezawa, Y .
ANALYTICA CHIMICA ACTA, 1997, 341 (2-3) :129-139
[4]   Thiocyanate-selective electrodes based on nickel and iron phthalocyanines [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYTICA CHIMICA ACTA, 1999, 402 (1-2) :137-143
[5]   PVC-based cobalt and manganese phthalocyanine coated graphite electrodes for determination of thiocyanate [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S .
ANALYTICAL LETTERS, 1999, 32 (14) :2737-2750
[6]   ANION SELECTIVITY OF METALLOPORPHYRINS IN MEMBRANES [J].
AMMANN, D ;
HUSER, M ;
KRAUTLER, B ;
RUSTERHOLZ, B ;
SCHULTHESS, P ;
LINDEMANN, B ;
HALDER, E ;
SIMON, W .
HELVETICA CHIMICA ACTA, 1986, 69 (04) :849-854
[7]  
Ardakani M. Mazloum, 2002, Analytica Chimica Acta, V462, P25
[8]  
Bakker E, 1999, ELECTROANAL, V11, P915, DOI 10.1002/(SICI)1521-4109(199909)11:13<915::AID-ELAN915>3.0.CO
[9]  
2-J
[10]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133