Ten years of preanalytical monitoring and control: Synthetic Balanced Score Card Indicator

被引:14
作者
Salinas, Maria [1 ,2 ]
Lopez-Garrigos, Maite [1 ,2 ]
Flores, Emilio [1 ,3 ]
Santo-Quiles, Ana [1 ]
Gutierrez, Mercedes [1 ]
Lugo, Javier [1 ]
Lillo, Rosa [1 ]
Leiva-Salinas, Carlos [4 ]
机构
[1] Hosp Univ San Juan, Clin Lab, Alacant, Spain
[2] Univ Miguel Hernandez, Dept Biochem & Mol Pathol, Elche, Spain
[3] Univ Miguel Hernandez, Dept Clin Med, Elche, Spain
[4] Univ Virginia, Dept Radiol, Charlottesville, VA USA
关键词
Preanalytical phase; errors in laboratory medicine; balanced scorecard; patient safety; CLINICAL LABORATORIES; QUALITY INDICATORS; ERRORS; MANAGEMENT; SPECIFICATIONS; IMPROVEMENT; MEDICINE; SAMPLES;
D O I
10.11613/BM.2015.005
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: Preanalytical control and monitoring continue to be an important issue for clinical laboratory professionals. The aim of the study was to evaluate a monitoring system of preanalytical errors regarding not suitable samples for analysis, based on different indicators; to compare such indicators in different phlebotomy centres; and finally to evaluate a single synthetic preanalytical indicator that may be included in the balanced scorecard management system (BSC). Materials and methods: We collected individual and global preanalytical errors in haematology, coagulation, chemistry, and urine samples analysis. We also analyzed a synthetic indicator that represents the sum of all types of preanalytical errors, expressed in a sigma level. We studied the evolution of those indicators over time and compared indicator results by way of the comparison of proportions and Chi-square. Results: There was a decrease in the number of errors along the years (P < 0.001). This pattern was confirmed in primary care patients, inpatients and outpatients. In blood samples, fewer errors occurred in outpatients, followed by inpatients. Conclusion: We present a practical and effective methodology to monitor unsuitable sample preanalytical errors. The synthetic indicator results summarize overall preanalytical sample errors, and can be used as part of BSC management system.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 28 条
[1]   Quality indicators and specifications for key processes in clinical laboratories:: a preliminary experience [J].
Alsina Kirchner, Ma Jesus ;
Alvarez Funes, Virtudes ;
Biosca Adzet, Carme ;
Domenech Clar, Ma Vicenta ;
Ibarz Escuer, Merce ;
Minchinela Girona, Joana ;
Pastor Barellas, Rosa Ma ;
Perich Alsina, Carmen ;
Ricos Aguila, Carmen ;
Trujillo Isern, Gloria ;
Vilanova Navarro, Conrad .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (05) :672-677
[2]   Preanalytical quality control program -: an overview of results (2001-2005 summary) [J].
Alsina, M. Jesus ;
Alvarez, Virtudes ;
Barba, Nuria ;
Bullich, Sandra ;
Cortes, Mariano ;
Escoda, Irene ;
Martinez-Bru, Cecilia .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (06) :849-854
[3]  
[Anonymous], REV CAL ASIST
[4]  
[Anonymous], CLIN LEADERSH MANAG
[5]  
Bonini P, 2002, CLIN CHEM, V48, P691
[6]   Creation of a synthetic indicator of quality of care as a clinical management standard in primary care [J].
Coma, Ermengol ;
Ferran, Manel ;
Mendez, Leonardo ;
Iglesias, Begona ;
Fina, Francesc ;
Medina, Manuel .
SPRINGERPLUS, 2013, 2 :1-11
[7]   Pre-analytical errors management in the clinical laboratory: a five-year study [J].
Gimenez-Marin, Angeles ;
Rivas-Ruiz, Francisco ;
del Mar Perez-Hidalgo, Maria ;
Molina-Mendoza, Pedro .
BIOCHEMIA MEDICA, 2014, 24 (02) :248-257
[8]  
Giyi C, 2005, 6 SIGMA DUMMIES
[9]   The cost of poor blood specimen quality and errors in preanalytical processes [J].
Green, Sol F. .
CLINICAL BIOCHEMISTRY, 2013, 46 (13-14) :1175-1179
[10]  
Jones BA, 1997, ARCH PATHOL LAB MED, V121, P19