Investigation of indoor climate and power usage in a data center

被引:37
作者
Karlsson, JF [1 ]
Moshfegh, B [1 ]
机构
[1] Linkoping Univ, Dept Mech Engn, Div Energy Syst, SE-58183 Linkoping, Sweden
关键词
data center; thermal management; power requirement; indoor climate; IR camera; visualization; airflow pattern;
D O I
10.1016/j.enbuild.2004.12.014
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal management of data centers is an important issue for many high technology companies. The power requirement to provide proper indoor climate in data centers is considerable. Thus, possibilities for energy savings and efficient electricity utilization are quite important. In this paper, the airflow and temperature patterns, as well as the electrical power requirement within a small data center, have been investigated. The power requirement within the data center is considerably high, due to an oversized air conditioning system. An infrared camera was used to visualize the airflow and temperature pattern, showing that cool air does not reach the upper levels of the racks, despite a very high air exchange rate. Point measurements of temperatures in a rack show that recirculation cells are present, causing accumulation of heat and improper cooling of electronic equipments. Thus, the chilled air is not distributed properly and consequently the cooling energy is not used effectively. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1075 / 1083
页数:9
相关论文
共 14 条
[1]   Forced convection air-cooling of a commercial electronic chassis: An experimental and computational case study [J].
Argento, CW ;
Joshi, YK ;
Osterman, MD .
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY PART A, 1996, 19 (02) :248-257
[2]   Infrared thermography for building diagnostics [J].
Balaras, CA ;
Argiriou, AA .
ENERGY AND BUILDINGS, 2002, 34 (02) :171-183
[3]   Measurements of air temperatures close to a low-velocity diffuser in displacement ventilation using an infrared camera [J].
Cehlin, M ;
Moshfegh, B ;
Sandberg, M .
ENERGY AND BUILDINGS, 2002, 34 (07) :687-698
[4]  
GIRALDO MD, 2001, P IPACK 01 8 13 JUL
[5]   A methodology for the design of perforated tiles in raised floor data centers using computational flow analysis [J].
Kang, SV ;
Schmidt, RR ;
Kelkar, KM ;
Radmehr, A ;
Patankar, SV .
IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2001, 24 (02) :177-183
[6]  
KARLSSON F, 2002, SCANDTHERM 2002 1 SC
[7]   Data center power requirements: measurements from Silicon Valley [J].
Mitchell-Jackson, J ;
Koomey, JG ;
Nordman, B ;
Blazek, A .
ENERGY, 2003, 28 (08) :837-850
[8]  
Patel C.D., 2002, P 2002 INT C THERM P
[9]   Computer and telecommunications equipment room cooling: A review of literature [J].
Schmidt, RR ;
Shaukatullah, H .
IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2003, 26 (01) :89-98
[10]  
SCHMIDT RR, 2001, P IPACK 01 JUL KAUAI