Model calculations of the radiation dose and LET spectra on LDEF and comparisons with flight data

被引:10
作者
Armstrong, TW [1 ]
Colborn, BL [1 ]
Benton, EV [1 ]
机构
[1] UNIV SAN FRANCISCO,SAN FRANCISCO,CA 94117
关键词
D O I
10.1016/S1350-4487(96)00080-7
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Ionizing radiation environment models, a 3-D spacecraft mass model, and radiation transport codes have been used to predict the radiation dose and linear energy transfer (LET) spectra measured at various locations on the LDEF satellite. The predictions are compared with thermoluminescent dosimeter measurements of the trapped proton and electron doses and with LET spectra measured by plastic nuclear track detectors. The predicted vs observed comparisons indicate some of the uncertainties of present ionizing radiation environment models for low Earth-orbit missions. Copyright (C) 1996 Elsevier Science Ltd
引用
收藏
页码:751 / 764
页数:14
相关论文
共 23 条
[11]  
BURRELL MO, 1964, X53063 NASA MARSH SP
[12]  
CHANG JY, 1991, NASA
[13]   Mass model of the LDEF satellite spacecraft and experiments for ionizing radiation analyses [J].
Colborn, BL ;
Armstrong, TW .
RADIATION MEASUREMENTS, 1996, 26 (06) :817-823
[14]  
DALY EJ, 1993, ESAESTECWMA93067ED
[15]  
DERRICKSON JH, 1992, NUCL TRACKS RAD MEAS, V20, P75
[16]  
FRANK AL, 1992, NASA
[17]  
REIT ZG, 1992, ADV SPACE RES, V12, P369
[18]   MEASUREMENT OF DIFFERENTIAL PROTON SPECTRA ONBOARD THE SPACE-SHUTTLE USING A THERMOLUMINESCENT DOSIMETRY SYSTEM [J].
RICHMOND, RG ;
BADHWAR, GD ;
CASH, B ;
ATWELL, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 256 (02) :393-397
[19]  
SAWYER DW, 1976, 7606 NSSDCWDCAR S GO
[20]  