Spatial resolution in Bragg-magnified X-ray images as determined by Fourier analysis

被引:47
作者
Modregger, Peter
Luebbert, Daniel
Schaefer, Peter
Koehler, Rolf
机构
[1] Humboldt Univ, Inst Phys, D-12489 Berlin, Germany
[2] Forschungszentrum Karlsruhe, Inst Synchroton Radiat, D-76344 Eggenstein Leopoldshafen, Germany
来源
PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE | 2007年 / 204卷 / 08期
关键词
D O I
10.1002/pssa.200675685
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The spatial resolution of an imaging system is most often experimentally determined by using model objects and idealized imaging conditions. This traditional approach does not properly take into account the influence of noise and the dependence of contrast on the object. The latter influence is essential especially in the case of magnified X-ray images acquired by two fold asymmetric Bragg diffraction. For this phase sensitive technique the application of a criterion for spatial resolution based upon Fourier analysis is shown to provide reliable resolution values in a simple way, overcoming the limitations mentioned above. For the case of Bragg-magnified imaging of an ant leg with 166 fold magnification (effective pixel size 0.094 mu m), the physical resolution achieved in the image is found to be 0.4 mu m. (c) 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
引用
收藏
页码:2746 / 2752
页数:7
相关论文
共 14 条
[1]  
Abbe E., 1873, ARCH MIKROSK ANAT, V9, P413, DOI [10.1007/BF02956173, DOI 10.1007/BF02956173]
[2]  
[Anonymous], BELL SYSTEM TECHNICA
[3]  
CARTWRIGHT M, 1990, FOURIER METHODS
[4]   Signal-to-noise optimization of medical imaging systems [J].
Cunningham, IA ;
Shaw, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (03) :621-632
[5]   Charge-coupled device area x-ray detectors [J].
Gruner, SM ;
Tate, MW ;
Eikenberry, EF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (08) :2815-2842
[6]   X-ray phase-contrast imaging with submicron resolution by using extremely asymmetric Bragg diffractions [J].
Kobayashi, K ;
Izumi, K ;
Kimura, H ;
Kimura, S ;
Ibuki, T ;
Yokoyama, Y ;
Tsusaka, Y ;
Kagoshima, Y ;
Matsui, J .
APPLIED PHYSICS LETTERS, 2001, 78 (01) :132-134
[7]   HARD X-RAY MICROSCOPE WITH SUBMICROMETER SPATIAL-RESOLUTION [J].
KURIYAMA, M ;
DOBBYN, RC ;
SPAL, RD ;
BURDETTE, HE ;
BLACK, DR .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1990, 95 (05) :559-574
[8]   Magnified x-ray phase imaging using asymmetric Bragg reflection:: Experiment and theory [J].
Modregger, Peter ;
Luebbert, Daniel ;
Schaefer, Peter ;
Koehler, Rolf .
PHYSICAL REVIEW B, 2006, 74 (05)
[9]  
Press W. H., 1992, SMR, V2nd
[10]  
Rayleigh L., 1879, Phil. Mag, V8, P261, DOI DOI 10.1080/14786447908639684