Reduced-scan schemes for x-ray fluorescence computed tomography

被引:13
作者
La Riviere, Patrick J. [1 ]
Vargas, Phillip
Newville, Matt
Sutton, Stephen R.
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Ctr Adv Radiat Sources, GSECARS, Argonne, IL 60439 USA
[3] Univ Chicago, Dept Geophys Sci, Chicago, IL 60637 USA
基金
美国国家科学基金会;
关键词
image reconstruction; penalized-likelihood; methods; X-ray fluorescence computed tomography;
D O I
10.1109/TNS.2007.906167
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
X-ray fluorescence computed tomography (XFCT) is a synchrotron-based imaging modality employed for mapping the distribution of elements within slices or volumes of intact specimens. A pencil beam of external radiation is used to stimulate emission of characteristic X-rays from within a sample, which is scanned and rotated through the pencil beam in a first-generation tomographic geometry. The measurements so obtained can be represented as generalizations of the attenuated Radon Transform. The range of angular scanning employed is the subject of some variability in the XFCT imaging community, as some groups rotate the object through a full 360 degrees, while others employ only a 180 degrees rotation. In both cases, the entire object is scanned through the beam at each projection view. The use of a 180 degrees rotation is sometimes justified by implicit reference to a well-known symmetry property of the Radon transform, but that symmetry does not hold for the attenuated Radon transform. In this work, we demonstrate that a full scan of the object at each view coupled with a 360 degrees rotation does contain a two-fold data redundancy. While the redundancy does not give rise to a simple symmetry condition as in the case of the Radon transform, we will show that it does indeed license the use of the 180 degrees scheme. However, we will also demonstrate that when there is a single external fluorescence detector, the redundancy also licenses a potentially more attractive reduced-scan scheme, in which the object is rotated through a full 360 degrees, but in which only the half of the object closest to the fluorescence detector is scanned at each projection view. This new scheme may permit both reduced imaging times and improved image quality.
引用
收藏
页码:1535 / 1542
页数:8
相关论文
共 17 条
[1]  
Barrett HH., 2004, FDN IMAGE SCI
[2]   FLUORESCENCE TOMOGRAPHY USING SYNCHROTRON RADIATION AT THE NSLS [J].
BOISSEAU, P ;
GRODZINS, L .
HYPERFINE INTERACTIONS, 1987, 33 (1-4) :283-292
[3]   A MODIFIED EXPECTATION MAXIMIZATION ALGORITHM FOR PENALIZED LIKELIHOOD ESTIMATION IN EMISSION TOMOGRAPHY [J].
DEPIERRO, AR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (01) :132-137
[4]   Nondestructive three-dimensional elemental microanalysis by combined helical x-ray microtomographies [J].
Golosio, B ;
Somogyi, A ;
Simionovici, A ;
Bleuet, P ;
Susini, J ;
Lemelle, L .
APPLIED PHYSICS LETTERS, 2004, 84 (12) :2199-2201
[5]   Internal elemental microanalysis combining x-ray fluorescence, Compton and transmission tomography [J].
Golosio, B ;
Simionovici, A ;
Somogyi, A ;
Lemelle, L ;
Chukalina, M ;
Brunetti, A .
JOURNAL OF APPLIED PHYSICS, 2003, 94 (01) :145-156
[6]   FLUORESCENT COMPUTER-TOMOGRAPHY - A MODEL FOR CORRECTION OF X-RAY ABSORPTION [J].
HOGAN, JP ;
GONSALVES, RA ;
KRIEGER, AS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (06) :1721-1727
[7]   Penalized-likelihood image reconstruction for x-ray fluorescence computed tomography [J].
La Riviere, Patrick J. ;
Billmire, David ;
Vargas, Phillip ;
Rivers, Mark ;
Sutton, Stephen R. .
OPTICAL ENGINEERING, 2006, 45 (07)
[8]   Monotonic penalized-likelihood image reconstruction for X-ray fluorescence computed tomography [J].
La Riviere, Patrick J. ;
Vargas, Phillip A. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (09) :1117-1129
[9]   Approximate analytic reconstruction in x-ray fluorescence computed tomography [J].
La Rivière, PJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) :2391-2405
[10]   Application of quantitative fluorescence and absorption-edge computed microtomography to image metal compartmentalization in Alyssum murale [J].
McNear, DH ;
Peltier, E ;
Everhart, J ;
Chaney, RL ;
Sutton, S ;
Newville, M ;
Rivers, M ;
Sparks, DL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (07) :2210-2218