Monotonic penalized-likelihood image reconstruction for X-ray fluorescence computed tomography

被引:47
作者
La Riviere, Patrick J. [1 ]
Vargas, Phillip A. [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
基金
美国国家科学基金会;
关键词
image reconstruction; penalized likelihood; X-ray fluorescence computed tomography (XFCT);
D O I
10.1109/TMI.2006.877441
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this paper, we derive a monotonic penalized-likelihood algorithm for image reconstruction in X-ray fluorescence computed tomography (XFCT) when the attenuation maps at the energies of the fluorescence X-rays are unknown. In XFCT, a sample is irradiated with pencil beams of monochromatic synchrotron radiation that stimulate the emission of fluorescence X-rays from atoms of elements whose K- or L-edges lie below the energy of the stimulating beam. Scanning and rotating the object through the beam allows for acquisition of a tomographic dataset that can be used to reconstruct images of the distribution of the elements in question. XFCT is a stimulated emission tomography modality, and it is thus necessary to correct for attenuation of the incident and fluorescence photons. The attenuation map is, however, generally known only at the stimulating beam energy and not at the energies of the various fluorescence X-rays of interest. We have developed a penalized-likelihood image reconstruction strategy for this problem. The approach alternates between updating the distribution of a given element and updating the attenuation map for that element's fluorescence X-rays. The approach is guaranteed to increase the penalized likelihood at each iteration. Because the joint objective function is not necessarily concave, the approach may drive the solution to a local maximum. To encourage the algorithm to seek out a reasonable local maximum, we include in the objective function a prior that encourages a relationship, based on physical considerations, between the fluorescence attenuation map and the distribution of the element being reconstructed.
引用
收藏
页码:1117 / 1129
页数:13
相关论文
共 28 条
[1]   FLUORESCENCE TOMOGRAPHY USING SYNCHROTRON RADIATION AT THE NSLS [J].
BOISSEAU, P ;
GRODZINS, L .
HYPERFINE INTERACTIONS, 1987, 33 (1-4) :283-292
[2]   APPROXIMATE RECONSTRUCTION OF ATTENUATION MAP IN SPECT IMAGING [J].
BRONNIKOV, AV .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (05) :1483-1488
[3]   NEW APPROACH TO THE EMISSION COMPUTERIZED TOMOGRAPHY PROBLEM - SIMULTANEOUS CALCULATION OF ATTENUATION AND ACTIVITY-COEFFICIENTS [J].
CENSOR, Y ;
GUSTAFSON, DE ;
LENT, A ;
TUY, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2775-2779
[4]   High resolution nuclear and X-ray microprobes and their applications in single cell analysis [J].
Cholewa, M ;
Dillon, C ;
Lay, P ;
Phillips, D ;
Talarico, T ;
Lai, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 181 (1-4) :715-722
[5]   ELEMENTAL COMPOSITION OF THE HUMAN ATHEROSCLEROTIC ARTERY WALL [J].
CICHOCKI, T ;
HECK, D ;
JARCZYK, L ;
ROKITA, E ;
STRZALKOWSKI, A ;
SYCH, M .
HISTOCHEMISTRY, 1985, 83 (01) :87-92
[6]  
CLINTHORNE NH, 1991, NUCL SCI S C REC, V3, P1927
[7]   Radiation background and beam quality in Secondary X-ray Imaging for human angiography with Au as contrast agent [J].
Csonka, PL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 556 (02) :589-606
[8]   Secondary X-ray imaging: an alternative approach to angiography and other applications [J].
Csonka, PL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 431 (1-2) :306-319
[9]   A MODIFIED EXPECTATION MAXIMIZATION ALGORITHM FOR PENALIZED LIKELIHOOD ESTIMATION IN EMISSION TOMOGRAPHY [J].
DEPIERRO, AR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (01) :132-137
[10]   Monotonic algorithms for transmission tomography [J].
Erdogan, H ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (09) :801-814