Heparin-coated cardiopulmonary bypass circuits: current status

被引:41
作者
Hsu, LC [1 ]
机构
[1] Edwards Lifesci LLC, Irvine, CA USA
来源
PERFUSION-UK | 2001年 / 16卷 / 05期
关键词
D O I
10.1177/026765910101600512
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Heparin-coated circuits have been subjected to vigorous testing, both experimentally and clinically, for the past decade. When the functions of heparin are preserved on the surface, the heparinized surface plays multiple roles in attenuating the systemic inflammatory response. These include the ability to attenuate contact activation, coagulation activation, complement activation and, directly or indirectly, platelet and leukocyte activation. The heparinized surface also renders the cardiopulmonary bypass (CPB) circuits hydrophilic and protein resistant and augments lipoprotein binding. The multifunctional nature of the heparinized surface contributes to the overall biocompatibility of the surface. Clinically, heparin-coated circuits become most effective in reducing systemic inflammatory response and in improving morbidity, mortality, and other patient outcome related parameters when material-independent blood activation is controlled or minimized through a global biocompatibility strategy. Techniques involved in the global biocompatibility strategy are readily available and are being effectively and safely practiced at several centers. With the global biocompatibility strategy, outstanding and reproducible results have been routinely achieved with conventional CPB techniques. Alternative revascularization procedures should equal or surpass conventional CPB, using best clinically proven strategies with respect to patient outcome and long-term graft patency.
引用
收藏
页码:417 / 428
页数:12
相关论文
共 68 条
[1]  
ALDEA G, 1998, ACC CURRENT J RE MAR, P45
[2]   Effect of anticoagulation protocol on outcome in patients undergoing CABG with heparin-bonded cardiopulmonary bypass circuits [J].
Aldea, GS ;
O'Gara, P ;
Shapira, OM ;
Treanor, P ;
Osman, A ;
Patalis, E ;
Arkin, C ;
Diamond, R ;
Babikian, V ;
Lazar, HL ;
Shemin, RJ .
ANNALS OF THORACIC SURGERY, 1998, 65 (02) :425-433
[3]   Heparin-bonded circuits improve clinical outcomes in emergency coronary artery bypass grafting [J].
Aldea, GS ;
Lilly, K ;
Gaudiani, JM ;
O'Gara, P ;
Stein, D ;
Bao, YS ;
Treanor, P ;
Osman, A ;
Shapira, OM ;
Lazar, HL ;
Shemin, RJ .
JOURNAL OF CARDIAC SURGERY, 1997, 12 (06) :389-397
[4]  
Aldea GS, 1996, ANN THORAC SURG, V62, P410, DOI 10.1016/0003-4975(96)00249-4
[5]  
Aldea GS, 1998, J CARDIAC SURG, V13, P81
[6]   The effect of cardiotomy suction on the brain injury marker S100β alter cardiopulmonary bypass [J].
Anderson, RE ;
Hansson, LC ;
Liska, J ;
Settergren, G ;
Vaage, J .
ANNALS OF THORACIC SURGERY, 2000, 69 (03) :847-850
[7]   Release of S100B during coronary artery bypass grafting is reduced by off-pump surgery [J].
Anderson, RE ;
Hansson, LO ;
Vaage, J .
ANNALS OF THORACIC SURGERY, 1999, 67 (06) :1721-1725
[8]   Comparison of three oxygenator-coated and one total-circuit-coated extracorporeal devices [J].
Baksaas, ST ;
Videm, V ;
Pedersen, T ;
Karlsen, H ;
Mollnes, TE ;
Brosstad, F ;
Svennevig, JL .
PERFUSION-UK, 1999, 14 (02) :119-127
[9]   Low heparinization with heparin-bonded bypass circuits: Is it a safe strategy? [J].
Bannan, S ;
Danby, A ;
Cowan, D ;
Ashraf, S ;
Martin, PG .
ANNALS OF THORACIC SURGERY, 1997, 63 (03) :663-668
[10]   Inflammatory response to cardiopulmonary bypass using two different types of heparin-coated extracorporeal circuits [J].
Baufreton, Christophe ;
Moczar, Madeleine ;
Intrator, Liliane ;
Jansen, Piet G. M. ;
te Velthuis, Henk ;
Le Besnerais, Paul ;
Farcet, Jean Pierre ;
Wildevuur, Charles R. H. ;
Loisance, Daniel Y. .
PERFUSION-UK, 1998, 13 (06) :419-427