The application of a chemical sensor array detector in ion chromatography for the determination of Na+, NH4+, K+, Mg2+ and Ca2+ in water samples

被引:34
作者
Shen, HD [1 ]
Cardwell, TJ [1 ]
Cattrall, RW [1 ]
机构
[1] La Trobe Univ, Dept Chem, Ctr Sci Instruments, Melbourne, Vic 3083, Australia
关键词
D O I
10.1039/a804100h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric sensor array detector was applied in ion chromatography (IC) for the determination of Na+, NH4+, K+, Mg2+ and Ca2+ in water samples with a detectability for these ions down to 0.02-0.1 mg l(-1). The results compare well with those obtained using AAS and flow injection reference methods. The advantages of this detector over the conductivity detector in IC are discussed. The detector has the capability of sensing up to eight different ions and the possibility of simultaneously determining both cations and anions in one sample is proposed.
引用
收藏
页码:2181 / 2184
页数:4
相关论文
共 29 条
[1]   MIXED POTENTIAL RESPONSE AT METALLIC ELECTRODES IN POTENTIOMETRIC DETECTION FOR ION CHROMATOGRAPHY [J].
ALEXANDER, PW ;
GLOD, BK ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1992, 589 (1-2) :201-207
[2]   Advances in detection techniques for ion chromatography [J].
Buchberger, WW ;
Haddad, PR .
JOURNAL OF CHROMATOGRAPHY A, 1997, 789 (1-2) :67-83
[3]   A MULTI-ION SENSOR CELL AND DATA-ACQUISITION SYSTEM FOR FLOW-INJECTION ANALYSIS [J].
CARDWELL, TJ ;
CATTRALL, RW ;
HAUSER, PC ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) :359-366
[4]   Simultaneous amperometric and potentiometric detection of inorganic anions in flow systems using platinum and silver silver chloride electrodes [J].
Chen, Z ;
Hibbert, DB .
ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) :1-6
[5]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF ACIDS AND ANIONS USING LIQUID MEMBRANE ION-SELECTIVE ELECTRODES IN A POTENTIOMETRIC FLOW-THROUGH DETECTOR [J].
DEBACKER, BL ;
NAGELS, LJ ;
ALDERWEIRELDT, FC ;
VANBOGAERT, PP .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :449-456
[6]   A POTENTIOMETRIC MEMBRANE CELL AS A DETECTOR IN LIQUID-CHROMATOGRAPHY [J].
DEELDER, RS ;
LINSSEN, HAJ ;
KOEN, JG ;
BEEREN, AJB .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :153-163
[7]   SERIAL POTENTIOMETRIC AND CONDUCTOMETRIC DETECTION IN FAST NON-SUPPRESSED ION CHROMATOGRAPHY APPLIED TO THE ANALYSIS OF FILTER COLLECTED AIRBORNE-PARTICULATES [J].
FRENZEL, W ;
RAUTERBERGWULFF, A ;
SCHEPERS, D .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 353 (02) :123-127
[8]   DETERMINATION OF SELECTIVITY COEFFICIENTS OF ION-SELECTIVE ELECTRODES BY A MATCHED-POTENTIAL METHOD [J].
GADZEKPO, VPY ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :279-282
[9]  
GOLD BK, 1992, J CHROMATOGR, V589, P209
[10]  
GOLD BK, 1995, J CHEOMATOGR A, V699, P31