SERIAL POTENTIOMETRIC AND CONDUCTOMETRIC DETECTION IN FAST NON-SUPPRESSED ION CHROMATOGRAPHY APPLIED TO THE ANALYSIS OF FILTER COLLECTED AIRBORNE-PARTICULATES

被引:6
作者
FRENZEL, W
RAUTERBERGWULFF, A
SCHEPERS, D
机构
[1] Institut für Technischen Umweltschutz, Fachgebiet Luftreinhaltung, Technische Universität Berlin, Berlin, D-10623
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1995年 / 353卷 / 02期
关键词
D O I
10.1007/BF00322944
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-suppressed ion chromatography (NSIC) has been optimized to permit the determination of chloride, nitrate and sulfate in the low mg/l concentration range within 3 min. Using conductometric detection the extraneous (positive) injection peak was found to adversely affect the early eluting chloride signal when samples with high amounts of total cations are analyzed. The serial arrangement of a downstream potentiometric detector with a chloride ion selective electrode, which does not respond to other alterations of the composition of the eluent than the change in chloride concentrations, is shown to be suitable for interference-free, sensitive and reliable chloride evaluation. Application of the proposed system to the determination of chloride in extracts of filter collected airborne particulates revealed (for those samples that could be evaluated by both detection methods) high precision and no systematic deviations between conductometric and potentiometric detection.
引用
收藏
页码:123 / 127
页数:5
相关论文
共 33 条
[1]  
BEHREND P, 1985, LABOR PRAXIS, V9, P324
[2]   APPLICATION OF ION-EXCHANGE CHROMATOGRAPHY WITH AN ION-SELECTIVE ELECTRODE DETECTOR TO IODINE DETERMINATION IN NATURAL-WATERS [J].
BUTLER, ECV ;
GERSHEY, RM .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :153-161
[3]   APPLICATION OF FLOW-INJECTION POTENTIOMETRY TO THE DETERMINATION OF CHLORIDE IN VARIOUS MATRICES [J].
FRENZEL, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (08) :931-937
[4]   MICROANALYTICAL CONCEPT FOR MULTICOMPONENT ANALYSIS OF AIRBORNE PARTICULATE MATTER [J].
FRENZEL, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 340 (09) :525-533
[5]   HIGH-SPEED DETERMINATION OF SULFATE BY NONSUPPRESSED ION CHROMATOGRAPHY [J].
FRENZEL, W ;
RAUTERBERG, A .
MIKROCHIMICA ACTA, 1992, 106 (3-6) :175-182
[6]  
FRENZEL W, 1994, 3 FLOW AN C TOL
[7]  
Haddad P. R., 1990, ION CHROMATOGRAPHY P
[8]   DETERMINATION OF SULFIDE AT THE PARTS-PER-BILLION LEVEL BY ION CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
HAN, K ;
KOCH, WF .
ANALYTICAL CHEMISTRY, 1987, 59 (07) :1016-1020
[9]  
HAN SH, 1993, J CHROMATOGR, V648, P283
[10]   DETERMINATION OF INORGANIC ANIONS AT PARTS PER BILLION LEVELS USING SINGLE-COLUMN ION CHROMATOGRAPHY WITHOUT SAMPLE PRECONCENTRATION [J].
HECKENBERG, AL ;
HADDAD, PR .
JOURNAL OF CHROMATOGRAPHY, 1984, 299 (01) :301-305