SERIAL POTENTIOMETRIC AND CONDUCTOMETRIC DETECTION IN FAST NON-SUPPRESSED ION CHROMATOGRAPHY APPLIED TO THE ANALYSIS OF FILTER COLLECTED AIRBORNE-PARTICULATES

被引:6
作者
FRENZEL, W
RAUTERBERGWULFF, A
SCHEPERS, D
机构
[1] Institut für Technischen Umweltschutz, Fachgebiet Luftreinhaltung, Technische Universität Berlin, Berlin, D-10623
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1995年 / 353卷 / 02期
关键词
D O I
10.1007/BF00322944
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-suppressed ion chromatography (NSIC) has been optimized to permit the determination of chloride, nitrate and sulfate in the low mg/l concentration range within 3 min. Using conductometric detection the extraneous (positive) injection peak was found to adversely affect the early eluting chloride signal when samples with high amounts of total cations are analyzed. The serial arrangement of a downstream potentiometric detector with a chloride ion selective electrode, which does not respond to other alterations of the composition of the eluent than the change in chloride concentrations, is shown to be suitable for interference-free, sensitive and reliable chloride evaluation. Application of the proposed system to the determination of chloride in extracts of filter collected airborne particulates revealed (for those samples that could be evaluated by both detection methods) high precision and no systematic deviations between conductometric and potentiometric detection.
引用
收藏
页码:123 / 127
页数:5
相关论文
共 33 条
[21]   SIMULTANEOUS CONDUCTIVITY AND POTENTIOMETRIC DETECTOR FOR MINIATURIZED LIQUID-CHROMATOGRAPHY AND FLOW-ANALYSIS [J].
SLAIS, K .
JOURNAL OF CHROMATOGRAPHY, 1991, 540 (1-2) :41-51
[22]   FAST DETERMINATION OF ANIONS BY COMPUTERIZED ION CHROMATOGRAPHY COUPLED WITH SELECTIVE DETECTORS [J].
SLANINA, J ;
BAKKER, FP ;
JONGEJAN, PAC ;
VANLAMOEN, L ;
MOLS, JJ .
ANALYTICA CHIMICA ACTA, 1981, 130 (01) :1-8
[23]   NOVEL ION-EXCHANGE CHROMATOGRAPHIC METHOD USING CONDUCTIMETRIC DETECTION [J].
SMALL, H ;
STEVENS, TS ;
BAUMAN, WC .
ANALYTICAL CHEMISTRY, 1975, 47 (11) :1801-1809
[24]   DETERMINATION OF FLUORIDE IN SEMICONDUCTOR PROCESS CHEMICALS BY ION CHROMATOGRAPHY WITH ION-SELECTIVE ELECTRODES [J].
TALASEK, RT .
JOURNAL OF CHROMATOGRAPHY, 1989, 465 (01) :1-10
[25]   THE DETERMINATION OF NON-OXIDIZABLE SPECIES USING ELECTROCHEMICAL DETECTION IN ION CHROMATOGRAPHY [J].
TARTER, JG .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 (08) :1559-1566
[26]  
TROJANOWICA M, 1982, ANAL CHIM ACTA, V183, P71
[27]   POTENTIOMETRIC FLOW-INJECTION DETERMINATION OF CHLORIDE [J].
TROJANOWICZ, M ;
MATUSZEWSKI, W .
ANALYTICA CHIMICA ACTA, 1983, 151 (01) :77-84
[28]   DIRECT AND REPLACEMENT ION CHROMATOGRAPHY WITH POTENTIOMETRIC DETECTION USING A SILVER SILVER BROMIDE ELECTRODE [J].
TROJANOWICZ, M ;
POBOZY, E ;
MEYERHOFF, ME .
ANALYTICA CHIMICA ACTA, 1989, 222 (01) :109-119
[29]   A COATED TUBULAR SOLID-STATE CHLORIDE-SELECTIVE ELECTRODE IN FLOW-INJECTION ANALYSIS [J].
VANSTADEN, JF .
ANALYTICA CHIMICA ACTA, 1986, 179 :407-417
[30]  
WHEALS BB, 1983, J CHROMATOGR, V262, P61