MICROANALYTICAL CONCEPT FOR MULTICOMPONENT ANALYSIS OF AIRBORNE PARTICULATE MATTER

被引:27
作者
FRENZEL, W
机构
[1] Institut für Technischen Umweltschutz, Fachgebiet Luftreinhaltung, Technische Universität Berlin, Berlin 12, W-1000
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1991年 / 340卷 / 09期
关键词
D O I
10.1007/BF00322423
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microanalytical concept is presented that permits the determination of four ionic species (NH4+, Cl-, NO3-, SO4(2)-) and 16 elements (Al, As, Cd, Ca, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Se, Si, V, Zn) in minute samples of filter collected atmospheric particulate matter. The multistage procedure is based on consecutive aqueous extraction and acid digestion of the entire sample. Ion analysis of the extract is made by flow injection analysis (FIA) and single column ion chromatography (SCIC) with total consumption of only 50-mu-l sample volume. Flame and furnace atomic absorption spectroscopy (AAS) is employed for element analysis after acid decomposition in a closed microwave digestion system. Using flow injection sample introduction for flame-AAS a liquid volume of 2 ml is sufficient for determination of 10 elements. Determination of the remaining 6 elements by graphite furnace AAS requires 1 ml. The quality assurance programme is briefly described. It includes the analysis of standard reference materials, intercomparison with other laboratories and the use of alternative methods for accuracy control.
引用
收藏
页码:525 / 533
页数:9
相关论文
共 47 条
[1]   EVALUATION OF EXTRACTION TECHNIQUES FOR DETERMINATION OF METALS IN AQUATIC SEDIMENTS [J].
AGEMIAN, H ;
CHAU, ASY .
ANALYST, 1976, 101 (1207) :761-767
[2]  
[Anonymous], 1978, SPECTROCHIM ACTA B, V33, P242
[3]  
BAUER WH, 1988, BESTIMMUNG URBANEN S
[4]  
BEHREND P, 1985, LABOR PRAXIS, V5, P326
[5]   MICROWAVE-OVEN SAMPLE DISSOLUTION FOR THE ANALYSIS OF ENVIRONMENTAL AND BIOLOGICAL-MATERIALS [J].
BETTINELLI, M ;
BARONI, U ;
PASTORELLI, N .
ANALYTICA CHIMICA ACTA, 1989, 225 (01) :159-174
[6]  
BUTLER FE, ION CHROMATOGRAPHIC, P65
[7]  
Cresser M. S., 1981, Progress in Analytical Atomic Spectroscopy, V4, P219
[8]   ANALYSIS OF SAMPLES WITH HIGH DISSOLVED SOLIDS CONTENT USING FLOW-INJECTION FLAME ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, Z ;
WELZ, B ;
SCHLEMMER, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (01) :91-95
[9]   APPLICATION OF FLOW-INJECTION POTENTIOMETRY TO THE DETERMINATION OF CHLORIDE IN VARIOUS MATRICES [J].
FRENZEL, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (08) :931-937
[10]   GAS-DIFFUSION SEPARATION AND FLOW-INJECTION POTENTIOMETRY - A FRUITFUL ALLIANCE OF ANALYTICAL METHODS [J].
FRENZEL, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 336 (01) :21-28