Integrated multimodal-catheter imaging unveils principal relationships among ventricular electrical activity, anatomy, and function

被引:4
作者
Rao, Liyun [1 ]
Ling, Yuesheng [1 ]
He, Renjie [2 ]
Gilbert, April L. [1 ]
Frangogiannis, Nikolaos G. [3 ]
Wang, Jianwen [1 ]
Nagueh, Sherif F. [1 ]
Khoury, Dirar S. [1 ]
机构
[1] Methodist Hosp, Res Inst, Methodist DeBakey Heart Ctr, Dept Cardiol, Houston, TX 77030 USA
[2] Univ Texas Houston, Hlth Sci Ctr, Dept Diagnost & Intervent Imaging, Houston, TX USA
[3] Baylor Coll Med, Dept Med, Cardiovasc Sci Sect, Houston, TX 77030 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2008年 / 294卷 / 02期
关键词
electrophysiology; myocardial infarction; noncontact mapping;
D O I
10.1152/ajpheart.01297.2006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Multiple imaging modalities are employed independent of one another while managing complex cardiac arrhythmias. To combine electrical, anatomical, and functional imaging in a single catheter system, we developed a balloon catheter that carried 64 electrodes on its surface and an intracardiac echocardiography (ICE) catheter through a central lumen. The catheter system was inserted, and the balloon was inflated inside the left ventricle (LV) of eight dogs with 6-wk-old infarction, created by occlusion in the left anterior descending coronary artery. Anatomy was constructed by ICE imaging (9 MHz) through the balloon. Single-beat noncontact mapping (NCM) was performed via the multielectrode array to reconstruct unipolar endocardial electrograms during sinus rhythm. Standard contact mapping (CM) of the endocardium was also carried out for reference. Myocardial infarction in anterior LV extending from the middle to apical regions was localized both by ICE and NCM and validated by CM and pathology. The overall difference in the activation times between NCM and CM was 3 +/- 1 ms. Unipolar voltage in infarcted middle anterior LV was smaller than the voltage in normal middle inferior LV both by NCM (11 +/- 4 vs. 16 +/- 3 mV; P = 0.002) and CM (11 +/- 3 vs. 20 +/- 4 mV; P = 0.001). Unipolar voltage was also inversely related to infarct transmurality, both by NCM (r = -0.87; P = 0.005) and CM (r = -0.94; P = 0.001). The infarct area by ICE (7.7 +/- 2.9 cm(2)) was in agreement with CM (bipolar voltage, <1 mV; and area, 7.6 +/- 3.3 cm(2); r = 0.80; P = 0.016). Meanwhile, the voltage threshold that depicted the infarct area by NCM was directly related to the smallest unipolar voltage reconstructed within the infarct (r = 0.96; P = 0.001). In conclusion, combining NCM and ICE imaging in a single catheter system is feasible. The preclinical development of such an integrated system and its evaluation in experimental myocardial infarction demonstrate capabilities for single-beat mapping at multiple sites as well as the online assessment of anatomy and myocardial function.
引用
收藏
页码:H1002 / H1009
页数:8
相关论文
共 30 条
[11]  
Gepstein L, 1997, CIRCULATION, V95, P1611
[12]   Characterization of the infarct substrate and ventricular tachycardia circuits with noncontact unipolar mapping in a porcine model of myocardial infarction [J].
Jacobson, JT ;
Afonso, VX ;
Eisenman, G ;
Schultz, JR ;
Lazar, S ;
Michele, JJ ;
Josephson, ME ;
Callans, DJ .
HEART RHYTHM, 2006, 3 (02) :189-197
[13]  
Khoury DS, 1998, CIRCULATION, V97, P399
[14]   RECONSTRUCTION OF ENDOCARDIAL POTENTIALS AND ACTIVATION SEQUENCES FROM INTRACAVITARY PROBE MEASUREMENTS - LOCALIZATION OF PACING SITES AND EFFECTS OF MYOCARDIAL STRUCTURE [J].
KHOURY, DS ;
TACCARDI, B ;
LUX, RL ;
ERSHLER, PR ;
RUDY, Y .
CIRCULATION, 1995, 91 (03) :845-863
[15]   A comparison of unipolar and bipolar electrodes during cardiac mapping studies [J].
Kimber, S ;
Downar, E ;
Masse, S ;
Sevaptsidis, E ;
Chen, T ;
Mickleborough, L ;
Parsons, I .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (08) :1196-1204
[16]   Phased-array intracardiac Echocardiography monitoring during pulmonary vein isolation in patients with atrial fibrillation - Impact on outcome and complications [J].
Marrouche, NF ;
Martin, DO ;
Wazni, O ;
Gillinov, AM ;
Klein, A ;
Bhargava, M ;
Saad, E ;
Bash, D ;
Yamada, H ;
Jaber, W ;
Schweikert, R ;
Tchou, P ;
Abdul-Karim, A ;
Saliba, W ;
Natale, A .
CIRCULATION, 2003, 107 (21) :2710-2716
[17]   Integration of 3-dimensional cardiac computed tomography images with real-time electroanatomic mapping to guide catheter ablation of atrial fibrillation [J].
Mikaelian, BJ ;
Malchano, ZJ ;
Neuzil, P ;
Weichet, J ;
Doshi, SK ;
Ruskin, JN ;
Reddy, VY .
CIRCULATION, 2005, 112 (02) :E35-E36
[18]   Evolution of mapping and anatomic imaging of cardiac arrhythmias [J].
Packer, DL .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (07) :839-854
[19]   Impact of myocardial structure and function postinfarction on diastolic strain measurements: implications for assessment of myocardial viability [J].
Park, TH ;
Nagueh, SF ;
Khoury, DS ;
Kopelen, HA ;
Akrivakis, S ;
Nasser, K ;
Ren, GF ;
Frangogiannis, NG .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2006, 290 (02) :H724-H731
[20]   Cardiac resynchronization therapy tailored by echocardiographic evaluation of ventricular asynchrony [J].
Pitzalis, MV ;
Iacoviello, M ;
Romito, R ;
Massari, F ;
Rizzon, B ;
Luzzi, G ;
Guida, P ;
Andriani, A ;
Mastropasqua, F ;
Rizzon, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (09) :1615-1622