An ICT-Based approach to ratiometric fluorescence imaging of hydrogen peroxide produced in living cells

被引:502
作者
Srikun, Duangkhae [1 ]
Miller, Evan W. [1 ]
Dornaille, Dylan W. [1 ]
Chang, Christopher J. [1 ]
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
关键词
D O I
10.1021/ja711480f
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We present the synthesis, properties, and biological applications of Peroxy Lucifer 1 (PL1), a new fluorescent probe for imaging hydrogen peroxide produced in living cells by a ratiometric response. PL1 utilizes a chemoselective boronate-based switch to detect hydrogen peroxide by modulation of internal charge transfer (ICT) within a 1,8-naphthalimide dye. PL1 features high selectivity for hydrogen peroxide over similar reactive oxygen species, including superoxide, and nitric oxide, and a 65 nm shift in emission from blue-colored fluorescence to green-colored fluorescence upon reaction with peroxide. Two-photon confocal microscopy experiments in live macrophages show that PL1 can ratiometrically visualize localized hydrogen peroxide bursts generated in living cells at immune response levels.
引用
收藏
页码:4596 / +
页数:3
相关论文
共 24 条
  • [1] THE SUPEROXIDE-FORMING ENZYMATIC SYSTEM OF PHAGOCYTES
    BELLAVITE, P
    [J]. FREE RADICAL BIOLOGY AND MEDICINE, 1988, 4 (04) : 225 - 261
  • [2] Genetically encoded fluorescent indicator for intracellular hydrogen peroxide
    Belousov, VV
    Fradkov, AF
    Lukyanov, KA
    Staroverov, DB
    Shakhbazov, KS
    Terskikh, AV
    Lukyanov, S
    [J]. NATURE METHODS, 2006, 3 (04) : 281 - 286
  • [3] A selective, cell-permeable optical probe for hydrogen peroxide in living cells
    Chang, MCY
    Pralle, A
    Isacoff, EY
    Chang, CJ
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (47) : 15392 - 15393
  • [4] Oxidants, oxidative stress and the biology of ageing
    Finkel, T
    Holbrook, NJ
    [J]. NATURE, 2000, 408 (6809) : 239 - 247
  • [5] Giorgio M, 2007, NAT REV MOL CELL BIO, V8, p722A
  • [6] A novel fluorescence ratiometric pH sensor based on covalently immobilized piperazinyl-1,8-napthalimide and benzothioxanthene
    Li, ZZ
    Niu, CG
    Zeng, GM
    Liu, YG
    Gao, PF
    Huang, GH
    Mao, YA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01): : 308 - 315
  • [7] A selective fluorescent ratiometric chemodosimeter for mercury ion
    Liu, B
    Tian, H
    [J]. CHEMICAL COMMUNICATIONS, 2005, (25) : 3156 - 3158
  • [8] Development of highly selective and sensitive probes for hydrogen peroxide
    Lo, LC
    Chu, CY
    [J]. CHEMICAL COMMUNICATIONS, 2003, (21) : 2728 - 2729
  • [9] Fluorescent probes for hydrogen peroxide based on a non-oxidative mechanism
    Maeda, H
    Futkuyasu, Y
    Yoshida, S
    Fukuda, M
    Saeki, K
    Matsuno, H
    Yamauchi, Y
    Yoshida, K
    Hirata, K
    Miyamoto, K
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2004, 43 (18) : 2389 - 2391
  • [10] Molecular imaging of hydrogen peroxide produced for cell signaling
    Miller, Evan W.
    Tulyanthan, Orapim
    Isacoff, Ehud Y.
    Chang, Christopher J.
    [J]. NATURE CHEMICAL BIOLOGY, 2007, 3 (05) : 263 - 267