Noninvasive measurement of concurrent single-kidney perfusion, glomerular filtration, and tubular function

被引:134
作者
Krier, JD
Ritman, EL
Bajzer, Z
Romero, JC
Lerman, A
Lerman, LO
机构
[1] Mayo Clin & Mayo Fdn, Dept Internal Med, Div Hypertens, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Dept Internal Med, Div Cardiovasc Dis, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Dept Physiol & Biophys, Rochester, MN 55905 USA
[4] Mayo Clin & Mayo Fdn, Dept Biochem & Mol Biol, Rochester, MN 55905 USA
关键词
renal blood flow; glomerular filtration rate; electron beam computed tomography;
D O I
10.1152/ajprenal.2001.281.4.F630
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
To assess the reliability of electron beam computed tomography (EBCT), measurements of single-kidney renal blood flow (RBF), glomerular filtration rate (GFR), and intratubular contrast medium concentration (ITC) of radiographic contrast media were quantified in anesthetized pigs before and after acetylcholine-induced vasodilation and diuresis. EBCT measurements were compared with those obtained with intravascular Doppler and inulin clearance. The capability of EBCT to detect chronic changes in single-kidney function was evaluated in pigs with unilateral renal artery stenosis, and their long-term reproducibility in normal pigs was studied repeatedly at 1-mo intervals. EBCT-RBF (ml/min) correlated with Doppler-RBF as RBF(EBCT) = 45 + 1.07 (*) RBF(Doppler), r = 0.81. EBCT-GFR (ml/min) correlated with inulin clearance as GFR(EBCT) = 11.7 + 1.02 (*) GFR(inulin), r = 0.80. During vasodilation, RBF and GFR increased, whereas ITC decreased along the nephron. In renal artery stenosis, single-kidney GFR decreased linearly with the degree of stenosis, and ITC increased along the nephron, indicating increased fluid reabsorption. EBCT-RBF, GFR, and ITC were similar among repeated measurements. This approach might be invaluable for simultaneous quantification of regional hemodynamics and function in the intact kidneys, in a manner potentially applicable to humans.
引用
收藏
页码:F630 / F638
页数:9
相关论文
共 41 条
[31]  
RUMBERGER JA, 1996, MARCUS CARDIAC IMAGI, P835
[32]   Quantitative evaluation of regional myocardial perfusion using fast x-ray computed tomography [J].
Schmermund, A ;
Bell, MR ;
Lerman, LO ;
Ritman, EL ;
Rumberger, JA .
HERZ, 1997, 22 (01) :29-39
[33]   CHANGES IN RENAL BLOOD FLOW, EXTRACTION OF INULIN, GLOMERULAR FILTRATION RATE, TISSUE PRESSURE AND URINE FLOW WITH ACUTE ALTERATIONS OF RENAL ARTERY BLOOD PRESSURE [J].
SHIPLEY, RE ;
STUDY, RS .
AMERICAN JOURNAL OF PHYSIOLOGY, 1951, 167 (03) :676-688
[34]   Nitric oxide and angiotensin II regulation of renal hemodynamics in the developing piglet [J].
Solhaug, MJ ;
Wallace, MR ;
Granger, JP .
PEDIATRIC RESEARCH, 1996, 39 (03) :527-533
[35]   ENDOTHELIUM-DERIVED NITRIC-OXIDE MODULATES RENAL HEMODYNAMICS IN THE DEVELOPING PIGLET [J].
SOLHAUG, MJ ;
WALLACE, MR ;
GRANGER, JP .
PEDIATRIC RESEARCH, 1993, 34 (06) :750-754
[36]  
STEINHAUSEN M, 1976, SITZUNGSBERICHTE HEI, P3
[37]   INDICATOR TRANSIT TIME CONSIDERED AS GAMMA VARIATE [J].
THOMPSON, HK ;
WHALEN, RE ;
STARMER, CF ;
MCINTOSH, HD .
CIRCULATION RESEARCH, 1964, 14 (06) :502-&
[38]  
TOJO A, 1994, J AM SOC NEPHROL, V4, P1438
[39]   PITFALLS IN MR MEASUREMENT OF TISSUE BLOOD-FLOW WITH INTRAVASCULAR TRACERS - WHICH MEAN TRANSIT-TIME [J].
WEISSKOFF, RM ;
CHESLER, D ;
BOXERMAN, JL ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (04) :553-559
[40]   INVIVO RELATION OF INTRAMYOCARDIAL BLOOD-VOLUME TO MYOCARDIAL PERFUSION - EVIDENCE SUPPORTING MICROVASCULAR SITE FOR AUTOREGULATION [J].
WU, XS ;
EWERT, DL ;
LIU, YH ;
RITMAN, EL .
CIRCULATION, 1992, 85 (02) :730-737