PCR-based detection in a micro-fabricated platform

被引:31
作者
Bhattacharya, Shantanu [1 ,2 ]
Salamat, Shuaib [1 ,2 ]
Morisette, Dallas [3 ]
Banada, Padmapriya [4 ]
Akin, Demir [1 ,5 ]
Liu, Yi-Shao [1 ,2 ]
Bhunia, Arun K. [4 ]
Ladisch, Michael [5 ]
Bashir, Rashid [1 ,2 ,5 ]
机构
[1] Purdue Univ, Birck Nanotechnol Ctr, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 47907 USA
[3] BioVitesse Inc, W Lafayette, IN USA
[4] Purdue Univ, Mol Food Microbiol Lab, W Lafayette, IN 47907 USA
[5] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
关键词
D O I
10.1039/b802227e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a novel, on-chip system for the electrokinetic capture of bacterial cells and their identification using the polymerase chain reaction (PCR). The system comprises a glass-silicon platform with a set of micro-channels, -chambers, and -electrodes. A platinum thin film resistor, placed in the proximity of the chambers, is used for temperature monitoring. The whole chip assembly is mounted on a Printed Circuit Board (PCB) and wire-bonded to it. The PCB has an embedded heater that is utilized for PCR thermal cycle and is controlled by a Lab-View program. Similar to our previous work, one set of electrodes on the chip inside the bigger chamber (0.6 mu l volume) is used for diverting bacterial cells from a flowing stream into to a smaller chamber (0.4 nl volume). A second set of interdigitated electrodes ( in smaller chamber) is used to actively trap and concentrate the bacterial cells using dielectrophoresis (DEP). In the presence of the DEP force, with the cells still entrapped in the micro-chamber, PCR mix is injected into the chamber. Subsequently, PCR amplification with SYBR Green detection is used for genetic identification of Listeria monocytogenes V7 cells. The increase in fluorescence is recorded with a photomultiplier tube module mounted over an epifluorescence microscope. This integrated micro-system is capable of genetic amplification and identification of as few as 60 cells of L. monocytogenes V7 in less than 90 min, in 600 nl volume collected from a sample of 104 cfu ml(-1). Specificity trials using various concentrations of L. monocytogenes V7, Listeria innocua F4248, and Escherichia coli O157:H7 were carried out successfully using two different primer sets specific for a regulatory gene of L. monocytogenes, prfA and 16S rRNA primer specific for the Listeria spp., and no cross-reactivity was observed.
引用
收藏
页码:1130 / 1136
页数:7
相关论文
共 37 条
[1]  
Alberts B., 2002, Molecular Biology of The Cell, V4th
[2]   Optimization of design and fabrication processes for realization of a PDMS-SOG-silicon DNA amplification chip [J].
Bhattacharya, Shantanu ;
Gao, Yuanfang ;
Korampally, Venumadhav ;
Othman, Maslina T. ;
Grant, Sheila A. ;
Kleiboeker, Steven B. ;
Gangopadhyay, Keshab ;
Gangopadhyay, Shubhra .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2007, 16 (02) :401-410
[3]   Evaluation of a real-time PCR kit for detecting Escherichia coli O157 in bovine fecal samples [J].
Bono, JL ;
Keen, JE ;
Miller, LC ;
Fox, JM ;
Chitko-McKown, CG ;
Heaton, MP ;
Laegreid, WW .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (03) :1855-1857
[4]  
Cabrera CR, 2001, ELECTROPHORESIS, V22, P355, DOI 10.1002/1522-2683(200101)22:2<355::AID-ELPS355>3.0.CO
[5]  
2-C
[6]   Chip PCR .2. Investigation of different PCR amplification systems in microfabricated silicon-glass chips [J].
Cheng, J ;
Shoffner, MA ;
Hvichia, GE ;
Kricka, LJ ;
Wilding, P .
NUCLEIC ACIDS RESEARCH, 1996, 24 (02) :380-385
[7]   BACTERIAL COLONY COUNTING USING MRC IMAGE ANALYZER [J].
COYNE, MB ;
FORAGE, AJ ;
PAICE, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1974, 19 (05) :708-715
[8]  
Edman CF, 2000, J INVEST MED, V48, P93
[9]  
ENCINAS BHL, 2004, ELECTROPHORESIS, V25, P1695
[10]  