Determination of the H3 factor in hydrogen isotope ratio monitoring mass spectrometry

被引:95
作者
Sessions, AL
Burgoyne, TW
Hayes, JM [1 ]
机构
[1] Woods Hole Oceanog Inst, Dept Geol & Geophys, Woods Hole, MA 02543 USA
[2] Indiana Univ, Dept Chem, Biogeochem Labs, Bloomington, IN 47405 USA
[3] Indiana Univ, Dept Geol Sci, Bloomington, IN 47405 USA
关键词
D O I
10.1021/ac000488m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The H-3 factor, K, is a parameter required in high-precision, mass spectrometric analyses of hydrogen isotopic abundances. When H-2 is used as the sample gas, R* = R - Ki(2), where R* is the true HD/H-2 ratio, R is the observed (mass 3)/(mass 2) ion-current ratio, and i(2) is the ion current at mass 2, Four different methods for the determination of K were defined and tested under conditions characteristic of isotope ratio monitoring systems, Three of these were peak-based. The fourth employed steady flows of H-2 from a conventional inlet system, Results obtained using the latter method were more precise (standard deviation of K = 0.1 versus similar to0.6 ppm mV(-1) for the peak-based methods). However, use of the resulting values of K for correction of isotope ratio monitoring GC/MS results led to systematic errors as large as 9 parts per thousand, whereas use of the peak-based values led to no systematic errors. Values of K were only weakly dependent on the pressure of He, declining similar to5% for each 10-fold increase in P-He. Small variations in partial pressures of H2O and CH4, potential contaminants under isotope ratio monitoring conditions, had no significant effect on values of K.
引用
收藏
页码:200 / 207
页数:8
相关论文
共 16 条
[1]   Quantitative production of H2 by pyrolysis of gas chromatographic effluents [J].
Burgoyne, TW ;
Hayes, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (24) :5136-5141
[2]   DEUTERIUM CONTENT OF NATURAL WATERS AND OTHER SUBSTANCES [J].
FRIEDMAN, I .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1953, 4 (1-2) :89-103
[3]  
Hilkert AW, 1999, RAPID COMMUN MASS SP, V13, P1226, DOI 10.1002/(SICI)1097-0231(19990715)13:13<1226::AID-RCM575>3.0.CO
[4]  
2-9
[5]  
Kelly SD, 1998, J MASS SPECTROM, V33, P735, DOI 10.1002/(SICI)1096-9888(199808)33:8<735::AID-JMS692>3.3.CO
[6]  
2-9
[7]   Water-induced errors in continuous-flow carbon isotope ratio mass spectrometry [J].
Leckrone, KJ ;
Hayes, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2737-2744
[8]   Efficiency and temperature dependence of water removal by membrane dryers [J].
Leckrone, KJ ;
Hayes, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (05) :911-918
[9]  
McLafferty F., 1980, Interpretation of Mass Spectra
[10]   PERFORMANCE AND OPTIMIZATION OF A COMBUSTION INTERFACE FOR ISOTOPE RATIO MONITORING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
MERRITT, DA ;
FREEMAN, KH ;
RICCI, MP ;
STUDLEY, SA ;
HAYES, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (14) :2461-2473