X-ray imaging and spectroscopy with Controlled-Drift Detectors:: experimental results and perspectives

被引:15
作者
Castoldi, A
Galimberti, A
Guazzoni, C
Rehak, P
Strüder, L
机构
[1] Politecn Milan, Dip Ingn Nucl, CeSNEF, I-20133 Milan, Italy
[2] Politecn Milan, Dip Elettron & Informaz, I-20133 Milan, Italy
[3] Brookhaven Natl Lab, Instrumentat Div, Upton, NY 11973 USA
[4] Max Planck Inst Halbleiterlab, D-81739 Munich, Germany
[5] Sincrotrone Trieste, SYRMEP Beamline, Trieste, Italy
关键词
time resolved X-ray imaging; X-ray radiography; Controlled-Drift Detectors; energy-resolved X-ray imaging;
D O I
10.1016/S0168-9002(03)01901-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Controlled-Drift Detector (CDD) is a fully depleted silicon detector that allows 2-D position sensing and energy spectroscopy of X-rays in the range 1-30 keV with excellent time resolution. Its distinctive feature is the simultaneous readout of the charge packets stored in the detector by means of a uniform electrostatic field leading to readout times of few mus/cm. The achieved room temperature energy resolution at the Mn Kalpha line is better than 300 eV FWHM at 60 kHz and improves at higher frame frequencies thanks to the short integration time. In this paper, we present the characterization of the imaging and timing properties of two CDD prototypes. Time resolved 2-D images in the microsecond range as well as X-ray radiographies will be presented. Details of the design of a new 6 x 6 mm(2) prototype will be presented and the preliminary measurements will be discussed. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:250 / 256
页数:7
相关论文
共 8 条
[1]   Spectroscopic-grade X-ray imaging up to 100-kHz frame rate with controlled-drift detectors [J].
Castoldi, A ;
Guazzoni, C ;
Rehak, P ;
Strüder, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) :982-986
[2]   Conception and design criteria of a novel silicon device for the measurement of position and energy of X rays [J].
Castoldi, A ;
Guazzoni, C ;
Longoni, A ;
Gatti, E ;
Rehak, P ;
Struder, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (05) :1724-1732
[3]   The controlled-drift detector [J].
Castoldi, A ;
Gatti, E ;
Guazzoni, C ;
Longoni, A ;
Rehak, P ;
Strüder, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 439 (2-3) :519-528
[4]  
CASTOLDI A, 2002, UNPUB NUCL INSTR M A
[5]  
CASTOLDI A, 2002, IEEE T NUCL SCI, V49
[6]   TIME-RESOLVED X-RAY-DIFFRACTION OF BIOLOGICAL-MATERIALS [J].
GRUNER, SM .
SCIENCE, 1987, 238 (4825) :305-312
[7]   Microsecond time-resolved 2D X-ray imaging [J].
Sarvestani, A ;
Sauer, N ;
Strietzel, C ;
Besch, HJ ;
Orthen, A ;
Pavel, N ;
Walenta, AH ;
Menk, RH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 465 (2-3) :354-364
[8]  
6249033