Microsecond time-resolved 2D X-ray imaging

被引:10
作者
Sarvestani, A
Sauer, N
Strietzel, C
Besch, HJ
Orthen, A
Pavel, N
Walenta, AH
Menk, RH
机构
[1] Sincrotrone Trieste, ELETTRA, Xray Detector Lab, I-34012 Trieste, Italy
[2] Univ Gesamthsch Siegen, Fachbereich Phys, D-57068 Siegen, Germany
关键词
X-ray detector; microsecond time resolution; radiography; tomography;
D O I
10.1016/S0168-9002(01)00699-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A method is presented which allows to take two-dimensional X-ray images of repetitive processes with recording times in the sub-microsecond range. Various measurements have been performed with a recently introduced novel two-dimensional single photon counter which has been slightly modified in order to determine the exact arrival time of each detected photon. For this purpose a special clock signal is synchronized with the process and is digitized contemporaneously with each event. This technique can be applied even with rate limited detectors and low flux sources, since-unlike in conventional methods, where chopped beams or gated read out electronics are used-all photons are used for the image formation. For the measurements, rapidly moving mechanical systems and conventional X-ray sources have been used, reaching time resolutions of some 10 mus. The technique presellted here opens a variety of new biological, medical and industrial applications which will be discussed. As a first application example, three dimensional tomographic reconstructions of rapidly rotating objects (4000 turns/min) are presented. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:354 / 364
页数:11
相关论文
共 10 条
[1]   An interpolating 2D pixel readout structure for synchrotron X-ray diffraction in protein crystallography [J].
Besch, HJ ;
Junk, M ;
Meissner, W ;
Sarvestani, A ;
Stiehler, R ;
Walenta, AH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :244-248
[2]  
CRUICKSHANK DWJ, 1992, PHIL T R SOC LOND A, P340
[3]   USE OF SYNCHROTRON RADIATION IN TIME-RESOLVED X-RAY-DIFFRACTION STUDIES OF MYOSIN LAYER LINE REFLECTIONS DURING MUSCLE-CONTRACTION [J].
HUXLEY, HE ;
FARUQI, AR ;
BORDAS, J ;
KOCH, MHJ ;
MILCH, JR .
NATURE, 1980, 284 (5752) :140-143
[4]   The ''RAPID'' high rate large area X-ray detector system [J].
Lewis, RA ;
Helsby, WI ;
Jones, AO ;
Hall, CJ ;
Parker, B ;
Sheldon, J ;
Clifford, P ;
Hillen, M ;
Sumner, I ;
Fore, NS ;
Jones, RWM ;
Roberts, KM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :32-41
[5]   Fast PC-based data acquisition system for gas-tilled position sensitive detectors [J].
Mio, H ;
Chemloul, M ;
Laggner, P ;
Amenitsch, H ;
Bernstorff, S ;
Rappolt, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :384-391
[6]   Time-resolved crystallography [J].
Moffat, K .
ACTA CRYSTALLOGRAPHICA SECTION A, 1998, 54 :833-841
[7]  
MOFFAT K, 1989, ANNU REV BIOPHYS BIO, V18, P309, DOI 10.1146/annurev.bb.18.060189.001521
[8]   Study and application of hole structures as gas gain devices for two dimensional high rate X-ray detectors [J].
Sarvestani, A ;
Besch, HJ ;
Junk, M ;
Meissner, W ;
Sauer, N ;
Stiehler, R ;
Walenta, AH ;
Menk, RH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 410 (02) :238-258
[9]  
SARVESTANI A, 1999, UNPUB J SYNCHROTRON
[10]   MILLISECOND MOLECULAR EVENTS IN DYNAMIC BIOLOGICAL-SYSTEMS RECORDED USING FAST AREA DETECTORS - CURRENT ACHIEVEMENTS AND FUTURE-NEEDS [J].
SQUIRE, JM ;
HARFORD, JJ ;
CHEW, MWK ;
BARRY, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2) :349-353