Electrochemical corrosion behaviour of uncoated and DLC coated medical grade Co28Cr6Mo

被引:56
作者
Dorner-Reisel, A
Schürer, C
Irmer, G
Müller, E
机构
[1] Freiberg Univ Min & Technol, Inst Ceram Mat, D-09596 Freiberg, Germany
[2] Inst Phys & Mech Technol Chemnitz, D-09117 Chemnitz, Germany
[3] Freiberg Univ Min & Technol, Inst Theoret Phys, D-09596 Freiberg, Germany
关键词
diamond-like carbon (DLC) coatings; electrochemical corrosion; thickness; Raman spectroscopy;
D O I
10.1016/j.surfcoat.2003.06.015
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The electrochemical corrosion resistance is one essential factor for determining the biocompatibility of metals. Although surgical alloys obtain an extraordinary high electrochemical corrosion resistance in the body environment, additional reduced metal ion release is expected to further improve the biocompatibility. In the following study, diamond-like carbon coatings with two different thickness were deposited on polished Co28Cr6Mo-samples (cast Protasul-2, ASTM standard F75, ISO standard 5832/4) by a plasma deposition method (direct current discharge) using gaseous hydrocarbon as precursor. The electrochemical behaviour of DLC is investigated in 0.89 wt.% NaCl solution and compared with the behaviour of the uncoated medical grade CoCrMo. Potentiodynamic polarization tests were carried out starting from the rest potential into the anodic direction up to a potential of + 1500 mV, and subsequently, into the cathodic direction. The polarization curves are evaluated and correlated to the thickness of the DLCs. Additional information is given by hardness measurements (loads 4 mN, 10 mN) as well as characterization of the nano- and microstructure (Raman spectroscopy). The shift of the break down potential to more positive values and the reduction of the current densities give evidence that DLC coatings provide an useful measure for reducing the corrosion attack of the cast Co28Cr6Mo-alloy in 89 wt.% NaCl. In this study, the 2.7-mum thick coating offers further improved protection in comparison with the 0.8-mum thick DLC. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:830 / 837
页数:8
相关论文
共 35 条
[1]   EFFECT OF INTRINSIC GROWTH STRESS ON THE RAMAN-SPECTRA OF VACUUM-ARC-DEPOSITED AMORPHOUS-CARBON FILMS [J].
AGER, JW ;
ANDERS, S ;
ANDERS, A ;
BROWN, IG .
APPLIED PHYSICS LETTERS, 1995, 66 (25) :3444-3446
[2]  
Amstutz H. C., 1996, CLIN ORTHOP S, V329, P11
[3]  
ASAMI K, 1978, CORROS SCI, V18, P151, DOI 10.1016/S0010-938X(78)80085-7
[4]   In vivo and in vitro evaluation of vitreous coatings on cobalt base alloys for prosthetic devices [J].
Ballarre, J ;
Orellano, JC ;
Bordenave, C ;
Galliano, P ;
Ceré, S .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 2002, 304 (1-3) :278-285
[5]   MODELING STUDIES OF AMORPHOUS-CARBON [J].
BEEMAN, D ;
SILVERMAN, J ;
LYNDS, R ;
ANDERSON, MR .
PHYSICAL REVIEW B, 1984, 30 (02) :870-875
[6]   In vitro corrosion testing of PVD coatings applied to a surgical grade Co-Cr-Mo alloy [J].
Bolton, J ;
Hu, X .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (06) :567-574
[7]  
DILLON RO, 1984, J APPL, V53, P3482
[8]   Improvement of the corrosion resistance of C/Al-composites by diamond-like carbon coatings [J].
Dorner, A ;
Wielage, B ;
Schürer, C .
THIN SOLID FILMS, 1999, 355 :214-218
[9]   Diamond-like carbon:: alteration of the biological acceptance due to Ca-O incorporation [J].
Dorner-Reisel, A ;
Schürer, C ;
Nischan, C ;
Seidel, O ;
Müller, E .
THIN SOLID FILMS, 2002, 420 :263-268
[10]   Ca-O-modified diamond-like carbon coatings synthesised by a direct current discharge [J].
Dorner-Reisel, A ;
Schürer, C ;
Reisel, G ;
Simon, F ;
Irmer, G ;
Müller, E .
THIN SOLID FILMS, 2001, 398 :180-186