Analysis of perchlorate in water and soil by electrospray LC/MS/MS

被引:57
作者
Winkler, P
Minteer, M
Willey, J
机构
[1] Time Solut Corp, Golden, CO 80403 USA
[2] Analyt Qual Associates, Albuquerque, NM 87123 USA
[3] Gen Engn Labs, Charleston, SC 29417 USA
关键词
D O I
10.1021/ac034618d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method has been developed for the determination of perchlorate in water and soil matrixes using electrospray liquid chromatography/mass spectrometry/mass spectrometry. Perchlorate is quantitated by monitoring the ion signal from mass 83, which is formed by a loss of an oxygen atom from the perchlorate molecular ion. The method was developed to be effective and economical in production laboratory analysis of perchlorate in environmental water and soil samples. Data were gathered to define method sensitivity; performance, selectivity, and robustness. Analyte stability, method susceptibility to interferences, and the reliability of the chlorine isotope ratio as an identification tool were examined. The aqueous method detection limit (MDL) is 0.05 mug/L and was determined using an actual groundwater matrix. The soil MDL is 0.5 mug/kg and was determined using Ottawa sand. The stability study was performed by spiking water samples at 0.25, 10, and 20 mug/L and analyzing them 50 days later. Acceptable recoveries were obtained for all samples. The relative standard deviation (RSD) for the replicate analyses in the stability study indicates that the method is capable of RSD values less than 5% in a relatively clean groundwater matrix. The ionization suppression study was performed by spiking water samples containing 1000 mg/L carbonate, chloride, and sulfate with 0.05 and 0.5 mug/L perchlorate and then measuring the recovery of the spike. The results indicate that the procedure does not have significant suppression effects at the high salt levels tested. Calibration, quality control sample, field sample, and suppression study data were combined to examine isotope ratio reliability. The results of that work show that chlorine isotope ratios can be used to define statistical process control limits for use as an additional analyte identification tool.
引用
收藏
页码:469 / 473
页数:5
相关论文
共 6 条
[1]  
*EPA, 2001, EPA REV M SACR CA FE
[2]   Analysis of perchlorate in groundwater by electrospray ionization mass spectrometry/mass spectrometry [J].
Koester, CJ ;
Beller, HR ;
Halden, RU .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (09) :1862-1864
[3]   Determination of perchlorate at trace levels in drinking water by ion-pair extraction with electrospray ionization mass spectrometry [J].
Magnuson, ML ;
Urbansky, ET ;
Kelty, CA .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :25-29
[4]  
*U S E P A, 1999, U S E P A REG 9 JUN
[5]   Quantitation of perchlorate ion: Practices and advances applied to the analysis of common matrices [J].
Urbansky, ET .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2000, 30 (04) :311-343
[6]  
US CODE FEDERAL 136, V40