Analysis of perchlorate in groundwater by electrospray ionization mass spectrometry/mass spectrometry

被引:71
作者
Koester, CJ [1 ]
Beller, HR [1 ]
Halden, RU [1 ]
机构
[1] Univ Calif Lawrence Livermore Natl Lab, Livermore, CA 94551 USA
关键词
D O I
10.1021/es991209j
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An electrospray ionization mass spectrometry/mass spectrometry (ESI/MS/MS) method was developed to measure part-per-billion (mu g/L) concentrations of perchlorate in groundwater. Selective and sensitive perchlorate detection was achieved by operating the mass spectrometer in the negative ionization mode and by using MS/MS to monitor the ClO4- to ClO3- transition. The method of sta nda rd additions was used to address the considerable signal suppression caused by anions that are typically present in groundwater, such as bicarbonate and sulfate. ESI/MS/MS analysis was rapid, accurate, reproducible, and provided a detection limit of 0.5 mu g/L perchlorate in groundwater. Accuracy and precision of the ESI/MS/MS method were assessed by analyzing performance evaluation samples in a groundwater matrix (4.5-75 mu g/L perchlorate) and by comparing ion chromatography (IC) and ESI/MS/MS results for local groundwater samples (<0.5-35 mu g/L perchlorate). Results for the performance evaluation samples differed from the certified values by 4-13%, and precision ranged from 3 to 10% (relative standard deviation). The IC and ESI/MS/MS results were statistically indistinguishable (P > 0.05) for perchlorate concentrations above the detection limits of both methods.
引用
收藏
页码:1862 / 1864
页数:3
相关论文
共 14 条
[1]  
BUHEMAN DL, 1996, J AM SOC MASS SPECTR, V7, P1099
[2]  
*CAL DEP HLTH SERV, 1999, OV CAL PERCHL EXP
[3]  
*CAL DEP HLTH SERV, 1997, DET PERCHL ION CHROM
[4]   Analysis of oxyhalides in water by ion chromatography ionspray mass spectrometry [J].
Charles, L ;
Pépin, D .
JOURNAL OF CHROMATOGRAPHY A, 1998, 804 (1-2) :105-111
[5]   Electrospray ion chromatography tandem mass spectrometry of oxyhalides at sub-ppb levels [J].
Charles, L ;
Pépin, D .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :353-359
[6]   Bromide/bromate speciation by NTI-IDMS and ICP-MS coupled with ion exchange chromatography [J].
Diemer, J ;
Heumann, KG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (01) :74-79
[7]  
*DION CORP, 1998, 099101 LPN DION CORP
[8]   TRACE ANALYSES FOR WASTEWATERS [J].
GLASER, JA ;
FOERST, DL ;
MCKEE, GD ;
QUAVE, SA ;
BUDDE, WL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1981, 15 (12) :1426-1435
[9]  
Kebarle P. A., 1993, ANAL CHEM, V65, P972
[10]  
RAMETTE RW, 1981, CHEM EQUILIBRIUM ANA, P73