L-cysteine voltammetry at a carbon paste electrode bulk-modified with ferrocenedicarboxylic acid

被引:100
作者
Raoof, Jahan-Bakhsh [1 ]
Ojani, Reza [1 ]
Beitollahi, Hadi [1 ]
机构
[1] Mazandaran Univ, Dept Chem, Electroanalyt Chem Res Lab, Fac Basic Sci, Babol Sar, Iran
关键词
ferrocenedicarboxylic acid; carbon paste electrode; L-cysteine; electrocatalysis; cyclic voltammetry;
D O I
10.1002/elan.200703932
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical behavior of L-cysteine studied at the surface of ferrocenedicarboxylic acid modified carbon paste electrode (FDCMCPE) in aqueous media using cyclic voltammetry, differential pulse voltammetry and double potential step chronoamperometry. It has been found that under optimum condition (pH 8.00) in cyclic voltammetry, the oxidation Of L-CySteine occurs at a potential about 200 mV less positive than that of an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, alpha, and catalytic reaction rate constant, k(h) were also determined using electrochemical approaches. The electrocatalytic oxidation peak current Of L-cysteine showed a linear dependent on the L-cysteine concentration and linear analytical curves were obtained in the ranges of 3.0 x 10(-5) M-2.2 x 10(-3) M and 1.5 x 10(-5) M - 3.2 x 10(-3) M Of L-cysteine concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (3 sigma) were determined as 2.6 x 10-5 M and 1.4 x 10(-6) M by CV and DPV methods. This method was also used for the determination of L-cysteine in patient-blood plasma and some pharmaceutical samples, such as acetylcysteine tablets and aminoplasma serum by using a standard addition method.
引用
收藏
页码:1822 / 1830
页数:9
相关论文
共 47 条
[1]   A new and practical carbon paste electrode for insoluble and ground samples [J].
Almeida, CMVB ;
Giannetti, BF .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (12) :985-988
[2]   The electrocatalytic reactions of cysteine and cystine by water-soluble iron porphyrin, manganese porphyrin and iron(II) phenanthrolines [J].
Chen, SM .
ELECTROCHIMICA ACTA, 1997, 42 (11) :1663-1673
[3]   Determination of cysteine in human plasma by high-performance liquid chromatography and ultraviolet detection after pre-column derivatization with 2-chloro-1-methylpyridinium iodide [J].
Chwatko, G ;
Bald, E .
TALANTA, 2000, 52 (03) :509-515
[4]   Determination of essential amino acids involved in the CD4-independent tropism of the X4 human immunodeficiency virus type 1 m7NDK isolate: Role of potential N glycosylations in the C2 and V3 regions of gp120 [J].
Dumonceaux, J ;
Goujon, C ;
Joliot, V ;
Briand, P ;
Hazan, U .
JOURNAL OF VIROLOGY, 2001, 75 (11) :5425-5428
[5]   Sensing of L-cysteine at glassy carbon electrode using Nile blue A as a mediator [J].
Ensafi, Ali A. ;
Behyan, Shirin .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) :282-288
[6]  
F Allen J Bard L.R., 2001, Electrochemical Methods: Fundamentals and Applications
[7]  
GALUS Z, 1976, FUDAMENTAL ELECTROCH
[8]   CHEMICALLY MODIFIED CARBON PASTE ELECTRODES .4. ELECTROSTATIC BINDING AND ELECTROCATALYSIS AT POLY(4-VINYLPYRIDINE)-CONTAINING ELECTRODES [J].
GENO, PW ;
RAVICHANDRAN, K ;
BALDWIN, RP .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 183 (1-2) :155-166
[9]   Catalysis of dioxygen reduction to hydrogen peroxide at the surface of carbon paste electrodes modified by 1,4-naphthoquinone and some of its derivatives [J].
Golabi, SM ;
Raoof, JB .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 416 (1-2) :75-82
[10]   Electrocatalytic and analytical responses of 10-methylphenothiazine toward reduced glutathione [J].
Gong, X ;
Li, HL .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2000, 147 (01) :238-241