Modeling and simulation of ionic currents in three-dimensional microfluidic devices with nanofluidic interconnects

被引:41
作者
Chatterjee, AN
Cannon, DM
Gatimu, EN
Sweedler, JV
Aluru, NR
Bohn, PW
机构
[1] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
[2] Univ Illinois, Dept Mech & Ind Engn, Urbana, IL 61801 USA
[3] Univ Illinois, Beckman Inst Adv Sci & Technol, Urbana, IL 61801 USA
关键词
nanofluidics; modeling; simulation; molecular gate; three-dimensional architecture; nanotechnology; water quality;
D O I
10.1007/s11051-005-5133-x
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electrokinetic fluid flow in nanocapillary array (NCA) membranes between vertically separated microfluidic channels offers an attractive alternative to using mechanical action to achieve fluidic communication between different regions of lab-on-a-chip devices. By adjusting the channel diameter, a, and the inverse Debye length, kappa, and applying the appropriate external potential, the nanochannel arrays, can be made to behave like digital fluidic switches, and the movement of molecules from one side of the array to the other side can be controlled. However, inherent differences in ionic mobility lead to non-equilibrium ion populations on the downstream side, which, in turn, shows up through transient changes in the microchannel conductance. Here we describe coupled calculations and experiments in which the electrical properties of a microfluidic-nanofluidic hybrid architecture are simulated by a combination of a compact model for the bulk electrical properties and iterative self-consistent solutions of the coupled Poisson, Nernst-Planck, and Navier-Stokes equations to recover the detailed ion motion in the nanopores. The transient electrical conductivity in the microchannel, after application of a forward bias pulse to the NCA membrane, is recovered in quantitative detail. The surface charge density of the nanopores and the capacitance of the membrane, which are critical determinants of electrokinetic flow through NCA, fall out of the analysis in a natural way, providing a clear mechanism to determine these critically important parameters.
引用
收藏
页码:507 / 516
页数:10
相关论文
共 25 条
[1]  
Berry RS., 1980, Physical Chemistry
[2]   Nanocapillary array interconnects for gated analyte injections and electrophoretic separations in multilayer microfluidic architectures [J].
Cannon, DM ;
Kuo, TC ;
Bohn, PW ;
Sweedler, JV .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2224-2230
[3]   Combined circuit/device modeling and simulation of integrated microfluidic systems [J].
Chatterjee, AN ;
Aluru, NR .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2005, 14 (01) :81-95
[4]   Protein transport in nanoporous membranes modified with self-assembled monolayers of functionalized thiols [J].
Chun, KY ;
Stroeve, P .
LANGMUIR, 2002, 18 (12) :4653-4658
[5]   Single-molecule detection of DNA separations in microfabricated capillary electrophoresis chips employing focused molecular streams [J].
Haab, BB ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 1999, 71 (22) :5137-5145
[6]   Separation of long DNA molecules in a microfabricated entropic trap array [J].
Han, J ;
Craighead, HG .
SCIENCE, 2000, 288 (5468) :1026-1029
[7]   Electric field mediated transport in nanometer diameter channels [J].
Kemery, PJ ;
Steehler, JK ;
Bohn, PW .
LANGMUIR, 1998, 14 (10) :2884-2889
[8]   Nanocapillary arrays effect mixing and reaction in multilayer fluidic structures [J].
Kuo, TC ;
Kim, HK ;
Cannon, DM ;
Shannon, MA ;
Sweedler, JV ;
Bohn, PW .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2004, 43 (14) :1862-1865
[9]   Gateable nanofluidic interconnects for multilayered microfluidic separation systems [J].
Kuo, TC ;
Cannon, DM ;
Chen, YN ;
Tulock, JJ ;
Shannon, MA ;
Sweedler, JV ;
Bohn, PW .
ANALYTICAL CHEMISTRY, 2003, 75 (08) :1861-1867
[10]   Hybrid three-dimensional nanofluidic/microfluidic devices using molecular gates [J].
Kuo, TC ;
Cannon, DM ;
Shannon, MA ;
Bohn, PW ;
Sweedler, JV .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 102 (03) :223-233