Electrical velocimetry demonstrates the increase in cardiac output and decrease in systemic vascular resistance accompanying cesarean delivery and oxytocin administration

被引:7
作者
Archer, Thomas L. [1 ]
Conrad, Benjamin E. [1 ]
Suresh, Preetham [1 ]
Tarsa, Maryam [2 ,3 ]
机构
[1] Univ Calif San Diego, Med Ctr, Dept Anesthesiol, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Med Ctr, Div Perinatal Med, San Diego, CA 92103 USA
[3] Univ Calif San Diego, Med Ctr, Dept Reprod Med, San Diego, CA 92103 USA
关键词
THERMODILUTION; HEMODYNAMICS; CHILDREN;
D O I
10.1016/j.jclinane.2011.02.014
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
引用
收藏
页码:79 / 82
页数:4
相关论文
共 10 条
[1]
Electrical velocimetry follows the hemodynamics of drug therapy and aortocaval compression in preeclampsia [J].
Archer, T. L. ;
Conrad, B. E. .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2011, 20 (01) :91-92
[2]
Electrical velocimetry elucidates the hemodynamics of hypertension caused by indigo carmine [J].
Archer, Thomas L. .
JOURNAL OF CLINICAL ANESTHESIA, 2011, 23 (02) :166-168
[3]
Hemodynamic Effects of Ephedrine, Phenylephrine, and the Coadministration of Phenylephrine with Oxytocin during Spinal Anesthesia for Elective Cesarean Delivery [J].
Dyer, Robert A. ;
Reed, Anthony R. ;
van Dyk, Dominique ;
Arcache, Michelle J. ;
Hodges, Owen ;
Lombard, Carl J. ;
Greenwood, Jaime ;
James, Michael F. .
ANESTHESIOLOGY, 2009, 111 (04) :753-765
[4]
Therapeutic optimization of atrioventricular delay in cardiosurgical ICU patients by noninvasive cardiac output measurements versus pulse contour analysis [J].
Mellert, F. ;
Lindner, P. ;
Schiller, W. ;
Gersing, E. ;
Heinze, I. ;
Kreuz, J. ;
Welz, A. ;
Preusse, C. J. .
THORACIC AND CARDIOVASCULAR SURGEON, 2008, 56 (05) :269-273
[5]
Electrical velocimetry for measuring cardiac output in children with congenital heart disease [J].
Norozi, K. ;
Beck, C. ;
Osthaus, W. A. ;
Wille, I. ;
Wessel, A. ;
Bertram, H. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (01) :88-94
[6]
Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in piglets [J].
Osthaus, Wilhelm Alexander ;
Huber, Dirk ;
Beck, Carsten ;
Winterhalter, Michael ;
Boethig, Dietmar ;
Wessel, Armin ;
Suempelmann, Robert .
PEDIATRIC ANESTHESIA, 2007, 17 (08) :749-755
[7]
Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output [J].
Schmidt, C ;
Theilmeier, G ;
Van Aken, H ;
Korsmeier, P ;
Wirtz, SP ;
Berendes, E ;
Hoffmeier, A ;
Meissner, A .
BRITISH JOURNAL OF ANAESTHESIA, 2005, 95 (05) :603-610
[8]
Maternal hemodynamics during cesarean delivery assessed by whole-body impedance cardiography [J].
Tihtonen, K ;
Kööbi, T ;
Yli-Hankala, A ;
Uotila, J .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2005, 84 (04) :355-361
[9]
Cardiac output measurement in children:: comparison of Aesculon® cardiac output monitor and thermodilution [J].
Tomaske, M. ;
Knirsch, W. ;
Kretschmar, O. ;
Woitzek, K. ;
Balmer, C. ;
Schmitz, A. ;
Bauersfeld, U. ;
Weiss, M. .
BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (04) :517-520
[10]
Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output [J].
Zoremba, N. ;
Bickenbach, J. ;
Krauss, B. ;
Rossaint, R. ;
Kuhlen, R. ;
Schaelte, G. .