Hemodynamic Effects of Ephedrine, Phenylephrine, and the Coadministration of Phenylephrine with Oxytocin during Spinal Anesthesia for Elective Cesarean Delivery

被引:256
作者
Dyer, Robert A. [1 ]
Reed, Anthony R. [1 ]
van Dyk, Dominique [1 ]
Arcache, Michelle J. [1 ]
Hodges, Owen [1 ]
Lombard, Carl J. [2 ]
Greenwood, Jaime [3 ]
James, Michael F. [1 ]
机构
[1] Univ Cape Town, Dept Anesthesia, ZA-7925 Cape Town, South Africa
[2] MRC, Biostat Unit, Cape Town, South Africa
[3] Univ Nottingham Hosp, NHS Trust, Nottingham NG7 2UH, England
关键词
CARDIAC-OUTPUT; IMPEDANCE CARDIOGRAPHY; SECTION; PREECLAMPSIA; HYPOTENSION; PRESSURE; FETAL; BODY;
D O I
10.1097/ALN.0b013e3181b437e0
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
Background: Hemodynamic responses to vasopressors used during spinal anesthesia for elective Cesarean delivery, have not been well described. This study compared the effects of bolus phenylephrine and ephedrine on maternal cardiac output (CO). The hypothesis was that phenylephrine, but not ephedrine, decreases CO, when administered in response to hypotension during spinal anesthesia. Methods: Forty-three patients were randomized to receive 80 mu g of phenylephrine or 10 mg of ephedrine. Both pulse wave form analysis and transthoracic bioimpedance changes were used to estimate stroke volume in each patient. Hemodynamic responses to spinal anesthesia and oxytocin were also recorded. A subgroup of 20 patients was randomized to receive oxytocin compared with oxytocin plus 80 mu g of phenylephrine after delivery. Results. Mean CO and maximum absolute response in CO were significantly lower during the 150 s after phenylephrine administration than after ephedrine (6.2 vs. 8.1 l/min, P = 0.001, and 5.2 vs. 9.0 l/min, P < 0.0001, respectively for pulse wave form analysis, and 5.2 vs. 6.3 l/min, P = 0.01 and 4.5 vs. 6.7 l/min, P = 0.0001, respectively for bioimpedance changes). CO changes correlated with heart rate changes. Coadministration of phenylephrine obtunded oxytocin-induced decreases in systemic vascular resistance and increases in heart rate and CO. Trends in CO change were similar using either monitor. Conclusions: Bolus phenylephrine reduced maternal CO, and decreased CO when compared with ephedrine during elective spinal anesthesia for Cesarean delivery. CO changes correlated with heart rate changes after vasopressor administration, emphasizing the importance of heart rate as a surrogate indicator of CO. Coadministered phenylephrine obtunded hemodynamic responses to oxytocin.
引用
收藏
页码:753 / 765
页数:13
相关论文
共 22 条
[1]
CONTROLLING THE FALSE DISCOVERY RATE - A PRACTICAL AND POWERFUL APPROACH TO MULTIPLE TESTING [J].
BENJAMINI, Y ;
HOCHBERG, Y .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1995, 57 (01) :289-300
[2]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]
Fetal and maternal effects of phenylephrine and ephedrine during spinal anesthesia for cesarean delivery [J].
Cooper, DW ;
Carpenter, M ;
Mowbray, P ;
Desira, WR ;
Ryall, DM ;
Kokri, MS .
ANESTHESIOLOGY, 2002, 97 (06) :1582-1590
[4]
The effect of peripheral resistance on impedance cardiography measurements in the anesthetized dog [J].
Critchley, LAH ;
Peng, ZY ;
Fok, BS ;
James, AE .
ANESTHESIA AND ANALGESIA, 2005, 100 (06) :1708-1712
[5]
A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[6]
Maternal Hemodynamic Monitoring in Obstetric Anesthesia [J].
Dyer, Robert A. ;
James, Michael F. .
ANESTHESIOLOGY, 2008, 109 (05) :765-767
[7]
Hemodynamic changes associated with spinal anesthesia for cesarean delivery in severe preeclampsia [J].
Dyer, Robert A. ;
Piercy, Jenna L. ;
Reed, Anthony P. ;
Lombard, Carl J. ;
Schoeman, Leann K. ;
James, Michael F. .
ANESTHESIOLOGY, 2008, 108 (05) :802-811
[8]
SYMPATHOVAGAL EFFECTS OF SPINAL-ANESTHESIA ASSESSED BY HEART-RATE-VARIABILITY ANALYSIS [J].
INTRONA, R ;
YODLOWSKI, E ;
PRUETT, J ;
MONTANO, N ;
PORTA, A ;
CRUMRINE, R .
ANESTHESIA AND ANALGESIA, 1995, 80 (02) :315-321
[9]
Perioperative bradycardia and asystole: relationship to vasovagal syncope and the Bezold-Jarisch reflex [J].
Kinsella, SM ;
Tuckey, JP .
BRITISH JOURNAL OF ANAESTHESIA, 2001, 86 (06) :859-868
[10]
Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output [J].
Kurita, T ;
Morita, K ;
Kato, S ;
Kikura, M ;
Horie, M ;
Ikeda, K .
BRITISH JOURNAL OF ANAESTHESIA, 1997, 79 (06) :770-775