Scanning near-field fluorescence resonance energy transfer microscopy

被引:56
作者
Vickery, SA [1 ]
Dunn, RC [1 ]
机构
[1] Univ Kansas, Dept Chem, Lawrence, KS 66045 USA
基金
美国国家科学基金会;
关键词
D O I
10.1016/S0006-3495(99)77341-8
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new microscopic technique is demonstrated that combines attributes from both near-field scanning optical microscopy (NSOM) and fluorescence resonance energy transfer (FRET). The method relies on attaching the acceptor dye of a FRET pair to the end of a near-field fiber optic probe. Light exiting the NSOM probe, which is nonresonant with the acceptor dye, excites the donor dye introduced into a sample. As the tip approaches the sample containing the donor dye, energy transfer from the excited donor to the tip-bound acceptor produces a red-shifted fluorescence. By monitoring this red-shifted acceptor emission, a dramatic reduction in the sample volume probed by the uncoated NSOM tip is observed. This technique is demonstrated by imaging the fluorescence from a multilayer film created using the Langmuir-Blodgett (LB) technique. The film consists of L-alpha-dipalmitoylphosphatidylcholine (DPPC) monolayers containing the donor dye, fluorescein, separated by a spacer group of three arachidic acid layers. A DPPC monolayer containing the acceptor dye, rhodamine, was also transferred onto an NSOM tip using the LB technique. Using this modified probe, fluorescence images of the multilayer film reveal distinct differences between images collected monitoring either the donor or acceptor emission. The latter results from energy transfer from the sample to the NSOM probe. This method is shown to provide enhanced depth sensitivity in fluorescence measurements, which may be particularly informative in studies On thick specimens such as cells. The technique also provides a mechanism for obtaining high spatial resolution without the need for a metal coating around the NSOM probe and Should work equally well with nonwaveguide probes such as atomic force microscopy tips. This may lead to dramatically improved spatial resolution in fluorescence imaging.
引用
收藏
页码:1812 / 1818
页数:7
相关论文
共 39 条
[1]   ALTERATIONS OF SINGLE-MOLECULE FLUORESCENCE LIFETIMES IN NEAR-FIELD OPTICAL MICROSCOPY [J].
AMBROSE, WP ;
GOODWIN, PM ;
MARTIN, JC ;
KELLER, RA .
SCIENCE, 1994, 265 (5170) :364-367
[2]   BREAKING THE DIFFRACTION BARRIER - OPTICAL MICROSCOPY ON A NANOMETRIC SCALE [J].
BETZIG, E ;
TRAUTMAN, JK ;
HARRIS, TD ;
WEINER, JS ;
KOSTELAK, RL .
SCIENCE, 1991, 251 (5000) :1468-1470
[3]   SINGLE MOLECULES OBSERVED BY NEAR-FIELD SCANNING OPTICAL MICROSCOPY [J].
BETZIG, E ;
CHICHESTER, RJ .
SCIENCE, 1993, 262 (5138) :1422-1425
[4]  
Betzig E., 1993, Bioimaging, V1, P129, DOI 10.1002/1361-6374(199309)1:3<129::AID-BIO1>3.3.CO
[5]  
2-#
[6]  
Brunner R, 1997, SURF INTERFACE ANAL, V25, P492, DOI 10.1002/(SICI)1096-9918(199706)25:7/8<492::AID-SIA256>3.0.CO
[7]  
2-0
[8]  
Cadenhead DA, 1980, ORDERING 2 DIMENSION, P73
[9]   Fluorescence resonance energy transfer study of shape changes in membrane-bound bovine prothrombin and meizothrombin [J].
Chen, Q ;
Lentz, BR .
BIOCHEMISTRY, 1997, 36 (15) :4701-4711
[10]   FLUORESCENCE RESONANCE ENERGY-TRANSFER SPECTROSCOPY IS A RELIABLE RULER FOR MEASURING STRUCTURAL-CHANGES IN PROTEINS - DISPELLING THE PROBLEM OF THE UNKNOWN ORIENTATION FACTOR [J].
DOSREMEDIOS, CG ;
MOENS, PDJ .
JOURNAL OF STRUCTURAL BIOLOGY, 1995, 115 (02) :175-185