Test-retest reliability of symptom-limited cycle ergometer tests in patients with chronic obstructive pulmonary disease

被引:23
作者
Covey, MK
Larson, JL
Alex, CG
Wirtz, S
Langbein, WE
机构
[1] Univ Illinois, Coll Nursing, Dept Med Surg Nursing, Chicago, IL 60612 USA
[2] Loyola Univ, Stritch Sch Med, Maywood, IL 60153 USA
[3] Edward Hines Jr VA Hosp, Res Serv, Hines, IL 60141 USA
关键词
exercise test; lung diseases (obstructive); reproducibility of results; exertional dyspnea;
D O I
10.1097/00006199-199901000-00003
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Background: Symptom-limited exercise tests are widely used to evaluate the effects of pulmonary rehabilitation in patients with chronic obstructive pulmonary disease (COPD), but the reliability of these tests is not well established in COPD patients. Objectives: We compared test-retest reliability of two repeated symptom-limited exercise tests between COPD patients and healthy elderly subjects and between male and female patients. Method: Fifty-six COPD patients (40 men, 16 women) and 16 healthy subjects (6 men, 10 women) performed two symptom-limited exercise tests approximately 2 weeks apart. Measures of oxygen uptake ((V) over dot O-2), minute ventilation ((V) over dot E), heart rate, and ratings of breathlessness and leg fatigue were obtained at peak exercise at each symptom-limited exercise test. Results: Repeated measures of peak exercise responses were stable for patients and healthy subjects and for male and female patients. Although mean percent error (absolute difference divided by mean) for peak exercise responses was low, some individuals' values exceeded 10%. There was no difference in the percent error between CORD patients and healthy subjects or between men and women with COPD. Test-retest reliability was lower for breathlessness ratings than for other peak exercise responses for all groups. Conclusions: Repeated symptom-limited exercise tests are reliable in COPD patients and healthy subjects. However, some individuals are less reliable, and these patients may require more than one exercise test to establish reliable performance.
引用
收藏
页码:9 / 19
页数:11
相关论文
共 50 条
[11]  
BROWN SE, 1985, AM REV RESPIR DIS, V131, P435
[12]  
CARTER R, 1988, ARCH PHYS MED REHAB, V69, P118
[13]   MULTIDISCIPLINARY TREATMENT OF CHRONIC PULMONARY INSUFFICIENCY .3. EFFECT OF PHYSICAL-TRAINING ON CARDIOPULMONARY PERFORMANCE IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY-DISEASE [J].
CHESTER, EH ;
BELMAN, MJ ;
BAHLER, RC ;
BAUM, GL ;
SCHEY, G ;
BUCH, P .
CHEST, 1977, 72 (06) :695-702
[14]   RANDOMIZED CONTROLLED TRIAL OF REHABILITATION IN CHRONIC RESPIRATORY DISABILITY [J].
COCKCROFT, AE ;
SAUNDERS, MJ ;
BERRY, G .
THORAX, 1981, 36 (03) :200-203
[15]   REPRODUCIBILITY OF INCREMENTAL MAXIMAL CYCLE ERGOMETER TESTS IN PATIENTS WITH MILD TO MODERATE OBSTRUCTIVE LUNG-DISEASES [J].
COX, NJM ;
HENDRIKS, JCM ;
BINKHORST, RA ;
FOLGERING, HTM ;
VANHERWAARDEN, CLA .
LUNG, 1989, 167 (02) :129-133
[16]   Applicability of VO2max criteria: Discontinuous versus continuous protocols [J].
Duncan, GE ;
Howley, ET ;
Johnson, BN .
MEDICINE & SCIENCE IN SPORTS & EXERCISE, 1997, 29 (02) :273-278
[17]   EFFECT OF PHYSICAL TRAINING ON CIRCULATION DURING PROLONGED SEVERE EXERCISE [J].
EKBLOM, B .
ACTA PHYSIOLOGICA SCANDINAVICA, 1970, 78 (02) :145-&
[18]   ASSESSMENT OF THE RELIABILITY OF PHYSICAL MEASURES [J].
ENGSTROM, JL .
RESEARCH IN NURSING & HEALTH, 1988, 11 (06) :383-389
[19]   THE REPRODUCIBILITY OF THE RESPIRATORY RESPONSES TO MAXIMUM EXERCISE [J].
GARRARD, CS ;
EMMONS, C .
RESPIRATION, 1986, 49 (02) :94-100
[20]  
GOLDMAN HI, 1959, AM REV TUBERC PULM, V79, P457