Accuracy of pulse oximetry in sickle cell disease

被引:53
作者
Ortiz, FO
Aldrich, TK
Nagel, RL
Benjamin, LJ
机构
[1] Montefiore Med Ctr, Div Pulm Med, Bronx, NY 10467 USA
[2] Montefiore Med Ctr, Div Hematol, Bronx, NY 10467 USA
[3] Montefiore Med Ctr, Ctr Comprehens Sickle Cell, Bronx, NY 10467 USA
[4] Albert Einstein Coll Med, Bronx, NY 10467 USA
关键词
D O I
10.1164/ajrccm.159.2.9806108
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Pulmonary complications and hypoxemia are common in sickle cell disease (SCD) and may exacerbate microvascular occlusive phenomena. Thus, detecting hypoxemia is of particular importance in SCD. To assess the accuracy of pulse oximetry in the diagnosis of hypoxemia in SCD, we compared 22 pulse oximetric measurements of arterial oxygen saturation (Sp(o2)) in adult patients with SCD and acute vasoocclusive crisis with simultaneously drawn arterial saturation (Sa(o2) = oxyhemoglobin divided by oxyhemoglobin plus reduced hemoglobin) measured by co-oximetry. We accepted Sp(o2) readings only if they were stable and characterized by strong and regular photoplethysmographic waves on the oximeter screen. To assess the position of these patients' oxyhemoglobin dissociation curves, we plotted arterial and venous oxygen saturation (Sa(o2) and Sv(o2)) against oxygen tension. We found right-shifted oxyhemoglobin dissociation curves, with pH-corrected p50s ranging from 28 to 38 mm Hg. Pulse oximetry slightly overestimated oxyhemoglobin percentage (by an average of 3.4 percentage points), but it almost always accurately estimated Sa(o2) (underestimating on average by 1.1 percentage points). The error in Sp(o2) was never enough to classify a hypoxemic patient erroneously as normoxemic or a normoxemic patient as hypoxemic. We conclude that, as long as strong and regular photoplethysmographic waves are present, pulse oximeters can be relied upon not to misdiagnose either hypoxemia or normoxemia in SCD.
引用
收藏
页码:447 / 451
页数:5
相关论文
共 16 条
[1]   Evaluation of pulse oximetry in sickle cell anemia patients presenting to the emergency department in acute vasoocclusive crisis [J].
Comber, JT ;
Lopez, BL .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1996, 14 (01) :16-18
[2]   COMPARISON OF OXYGENATION MEASUREMENTS IN PEDIATRIC-PATIENTS DURING SICKLE-CELL CRISES [J].
CRAFT, JA ;
ALESSANDRINI, E ;
KENNEY, LB ;
KLEIN, B ;
BRAY, G ;
LUBAN, NLC ;
MEEK, R ;
NADKARNI, VM .
JOURNAL OF PEDIATRICS, 1994, 124 (01) :93-95
[3]  
Eaton William A., 1994, P53
[4]  
May A, 1972, Hamatol Bluttransfus, V10, P279
[5]  
Nagel R. L., 1998, PULMONARY CRITICAL C, P1
[6]  
OESEBURG B, 1994, ADV EXP MED BIOL, V345, P925
[7]   PULSE OXIMETRY IN SICKLE-CELL DISEASE [J].
PIANOSI, P ;
CHARGE, TD ;
ESSELTINE, DW ;
COATES, AL .
ARCHIVES OF DISEASE IN CHILDHOOD, 1993, 68 (06) :735-738
[8]  
RACKOFF WR, 1993, BLOOD, V81, P3422
[9]  
SEVERINGHAUS JW, 1992, ANESTHESIOLOGY, V76, P1018
[10]   SIMPLE, ACCURATE EQUATIONS FOR HUMAN-BLOOD O2 DISSOCIATION COMPUTATIONS [J].
SEVERINGHAUS, JW .