Theory and practice of enzyme bioaffinity electrodes.: Direct electrochemical product detection

被引:39
作者
Limoges, Benoit [1 ]
Marchal, Damien [1 ]
Mavre, Francois [1 ]
Saveant, Jean-Michel [1 ]
Schoellhorn, Bernd [2 ]
机构
[1] Univ Paris Diderot, Electrochim Mol Lab, CNRS, UMR 7591, F-75251 Paris 05, France
[2] Ecole Normale Super, UMR CNRS PASTEUR 8640, Dept Chim, F-75231 Paris 05, France
关键词
D O I
10.1021/ja7102845
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The use of enzyme labeling techniques to convert biorecognition events into high sensitivity electrochemical signals may follow two different strategies. One, in which the current is the electrocatalytic response of a redox couple serving as cosubstrate to a redox enzyme label and another that consists in the detection of an electrochemically active product of the enzyme label. The theoretical relationships that link, in the latter case, the electrochemical current response to the amount of recognized labeled target analyte are established for steady-state diffusion-convection chronoamperometric regimes. Two governing parameters thus emerge. One measures the Michaelis-Menten competition in the enzyme kinetics. The other characterizes the competition between the enzymatic kinetics and the diffusion of the substrate. The electrochemical response is finally related to the labeled target analyte concentration in solution through the recognition isotherm. The direct electrochemical product detection thus provides a route to the characteristics of the recognition isotherm, which serves as a calibration curve in analytical applications. The establishment of further theoretical relationships allows one to surmise the increase in sensitivity that may be obtained by using cyclic voltammetry instead of steady-state chronoamperometry in standard electrochemical cells or by accumulation of the enzyme-product in cells of small volume/surface ratios. The theoretical predictions are tested with the example of the avidin-biotin recognition process in a system that involves alkaline phosphatase as enzyme label and 4-amino-2,6-dichlorophenyl phosphate as substrate, generating 4-amino-2,6-dichlorophenol as electrochemically active product. The advantages of the dichloro-substitution are discussed. The theoretical analysis is a requisite for a rational and realistic discussion of the analytical performances of the steady-state chronoamperometric and cyclic voltammetric approaches. These are shown to compare favorably with the best heterogeneous bioaffinity assays so far reported.
引用
收藏
页码:7259 / 7275
页数:17
相关论文
共 87 条
[11]   Detection of protein analytes via nanoparticle-based bio bar code technology [J].
Bao, YP ;
Wei, TF ;
Lefebvre, PA ;
An, H ;
He, LX ;
Kunkel, GT ;
Müller, UR .
ANALYTICAL CHEMISTRY, 2006, 78 (06) :2055-2059
[12]   Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid [J].
Bauer, CG ;
Eremenko, AV ;
EhrentreichForster, E ;
Bier, FF ;
Makower, A ;
Halsall, HB ;
Heineman, WR ;
Scheller, FW .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2453-2458
[13]  
Bayer E A, 1980, Methods Biochem Anal, V26, P1
[14]   A FULLY ACTIVE MONOLAYER ENZYME ELECTRODE DERIVATIZED BY ANTIGEN-ANTIBODY ATTACHMENT [J].
BOURDILLON, C ;
DEMAILLE, C ;
GUERIS, J ;
MOIROUX, J ;
SAVEANT, JM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (26) :12264-12269
[15]   Activation and diffusion in the kinetics of adsorption and molecular recognition on surfaces.: Enzyme-amplified electrochemical approach to biorecognition dynamics illustrated by the binding of antibodies to immobilized antigens [J].
Bourdillon, C ;
Demaille, C ;
Moiroux, J ;
Savéant, JM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (11) :2401-2408
[16]   Disposable amperometric immunosensor for the detection of 17-β estradiol using screen-printed electrodes [J].
Butler, D ;
Guilbault, GG .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02) :692-699
[17]   Towards immunoassay in whole blood: separationless sandwich-type electrochemical immunoassay based on in-situ generation of the substrate of the labeling enzyme [J].
Campbell, CN ;
de Lumley-Woodyear, T ;
Heller, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (1-2) :165-169
[18]   Oligonucleotide-modified screen-printed gold electrodes for enzyme-amplified sensing of nucleic acids [J].
Carpini, G ;
Lucarelli, F ;
Marrazza, G ;
Mascini, M .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (02) :167-175
[19]   Enzyme-amplified amperometric detection of hybridization and of a single base pair mutation in an 18-base oligonucleotide on a 7-μm-diameter microelectrode [J].
Caruana, DJ ;
Heller, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (04) :769-774
[20]  
CIANA LD, 1995, J ELECTROANAL CHEM, V382, P129