Critical evaluation of methodology commonly used in sample collection, storage and preparation for the analysis of pharmaceuticals and illicit drugs in surface water and wastewater by solid phase extraction and liquid chromatography-mass spectrometry

被引:206
作者
Baker, David R. [2 ]
Kasprzyk-Hordern, Barbara [1 ]
机构
[1] Univ Bath, Dept Chem, Fac Sci, Bath BA2 7AY, Avon, England
[2] Univ Huddersfield, Dept Chem & Biol Sci, Sch Appl Sci, Huddersfield HD1 3DH, W Yorkshire, England
关键词
Illicit drugs; Drugs of abuse; Pharmaceuticals; Wastewater; Surface water; River water; Environment; LC-MS/MS; Sewage; SPE; Multi-residue; Silanisation; Stability study; Sample preparation; Sewage forensics; Sewage epidemiology; PERSONAL CARE PRODUCTS; LC-MS/MS; METABOLITES; ABUSE; COCAINE; URINE; IDENTIFICATION; CANNABINOIDS; AMPHETAMINE; WASTEWATERS;
D O I
10.1016/j.chroma.2011.09.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The main aim of this manuscript is to provide a comprehensive and critical verification of methodology commonly used for sample collection, storage and preparation in studies concerning the analysis of pharmaceuticals and illicit drugs in aqueous environmental samples with the usage of SPE-LC/MS techniques. This manuscript reports the results of investigations into several sample preparation parameters that to the authors' knowledge have not been reported or have received very little attention. This includes: (i) effect of evaporation temperature and (ii) solvent with regards to solid phase extraction (SPE) extracts; (iii) effect of silanising glassware; (iv) recovery of analytes during vacuum filtration through glass fibre filters and (v) pre LC-MS filter membranes. All of these parameters are vital to develop efficient and reliable extraction techniques; an essential factor given that target drug residues are often present in the aqueous environment at ng L-1 levels. Presented is also the first comprehensive review of the stability of illicit drugs and pharmaceuticals in wastewater. Among the parameters studied are: time of storage, temperature and pH. Over 60 analytes were targeted including stimulants, opioid and morphine derivatives, benzodiazepines, antidepressants, dissociative anaesthetics, drug precursors, human urine indicators and their metabolites. The lack of stability of analytes in raw wastewater was found to be significant for many compounds. For instance, 34% of compounds studied reported a stability change >15% after only 12 h in raw wastewater stored at 2 degrees C; a very important finding given that wastewater is typically collected with the use of 24 h composite samplers. The stability of these compounds is also critical given the recent development of so-called 'sewage forensics' or 'sewage epidemiology' in which concentrations of target drug residues in wastewater are used to back-calculate drug consumption. Without an understanding of stability, under (or over) reporting of consumption estimations may take place. (c) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:8036 / 8059
页数:24
相关论文
共 40 条
[31]   Fully automated determination in the low nanogram per liter level of different classes of drugs of abuse in sewage water by on-line solid-phase extraction-liquid chromatography-electrospray-tandem mass spectrometry [J].
Postigo, Cristina ;
de Alda, Maria J. Lopez ;
Barcelo, Damia .
ANALYTICAL CHEMISTRY, 2008, 80 (09) :3123-3134
[32]   The quantitative analysis of heroin, methadone and their metabolites and the simultaneous detection of cocaine, acetylcodeine and their metabolites in human plasma by high-performance liquid chromatography coupled with tandem mass spectrometry [J].
Rook, EJ ;
Hillebrand, MJX ;
Rosing, H ;
van Ree, JM ;
Beijnen, JH .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 824 (1-2) :213-221
[33]   Monitoring of opiates, cannabinoids and their metabolites in wastewater, surface water and finished water in Catalonia, Spain [J].
Rosa Boleda, M. ;
Teresa Galceran, M. ;
Ventura, Francesc .
WATER RESEARCH, 2009, 43 (04) :1126-1136
[34]   Trace analysis of antidepressant pharmaceuticals and their select degradates in aquatic matrixes by LC/ESI/MS/MS [J].
Schultzt, Melissa M. ;
Furlong, Edward T. .
ANALYTICAL CHEMISTRY, 2008, 80 (05) :1756-1762
[35]  
Seed B., 1997, Curr. Protoc. Immunol, pA.3k.1
[36]   Simultaneous determination of 15 top-prescribed pharmaceuticals and their metabolites in influent wastewater by reversed-phase liquid chromatography coupled to tandem mass spectrometry [J].
Tarcomnicu, Isabela ;
van Nuijs, Alexander L. N. ;
Simons, Ward ;
Bervoets, Lieven ;
Blust, Ronny ;
Jorens, Philippe G. ;
Neels, Hugo ;
Covaci, Adrian .
TALANTA, 2011, 83 (03) :795-803
[37]  
USEPA (United States Environmental Protection Agency), 2010, STAB PHARM PERS CAR
[38]   Analysis of drugs of abuse in wastewater by hydrophilic interaction liquid chromatography-tandem mass spectrometry [J].
van Nuijs, Alexander L. N. ;
Tarcomnicu, Isabela ;
Bervoets, Lieven ;
Blust, Ronny ;
Jorens, Philippe G. ;
Neels, Hugo ;
Covaci, Adrian .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (03) :819-828
[39]   SPE and LC-MS/MS determination of 14 illicit drugs in surface waters from the Natural Park of L'Albufera (ValSncia, Spain) [J].
Vazquez-Roig, Pablo ;
Andreu, Vicente ;
Blasco, Cristina ;
Pico, Yolanda ;
Andreu, V. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (07) :2851-2864
[40]  
Zuccato E, 2008, ENV HLTH PERSPECT, V116