Cytometric analysis of protein expression and apoptosis in human primary cells with a novel microfluidic chip-based system

被引:48
作者
Chan, SDH
Luedke, G
Valer, M
Buhlmann, C
Preckel, T
机构
[1] Agilent Technol GmbH, D-76337 Waldbronn, Germany
[2] Caliper Technol, Mountain View, CA USA
关键词
microfluidic; lab-on-a-chip; flow cytometry; primary cells; protein expression; apoptosis;
D O I
10.1002/cyto.a.10070
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Work with primary cells is inherently limited by source availability and life span in culture. Flow cytometry offers extensive analytical opportunities but generally requires high cell numbers for an experiment. Methods: We have developed assays on a microfluidic system, which allow flow cytometric analysis of apoptosis and protein expression with a minimum number of fluorescently stained primary cells. In this setup, the cells are moved by pressure-driven flow inside a network of microfluidic channels and are analyzed individually by two-channel fluorescence detection. For some assays the staining reactions can be performed on-chip and the analysis is done without further washing steps. Results: We have successfully applied the assays to evaluate (a) activation of E-selectin (CD62E) expression by interleukin-1beta in human umbilical vein endothelial cells (HUVECs), (b) induction of CD3 by phorbol-12-myristate-13-acetate in freshly prepared human peripheral blood lymphocytes, and (c) staurosporine-induced apoptosis in HUVEC and normal human dermal fibroblasts. Conclusions: Results obtained with the microfluidic system are in good correlation with data obtained using a standard flow cytometer, but demonstrate new dimensions in low reagent and cell consumption. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:119 / 125
页数:7
相关论文
共 16 条
[1]   A new cytometric method for the immunophenotypic characterization of bone-derived human osteoclasts [J].
Benito, GE ;
Sánchez, ML ;
del Pino-Montes, J ;
Calvo, JJ ;
Menéndez, P ;
García-Marcos, MA ;
Osdoby, P ;
Orfao, A .
CYTOMETRY, 2002, 50 (05) :261-266
[2]   Molecular mechanism of staurosporine-induced apoptosis in osteoblasts [J].
Chae, HJ ;
Kang, JS ;
Byun, JO ;
Han, KS ;
Kim, DU ;
Oh, SM ;
Kim, HM ;
Chae, SW ;
Kim, HR .
PHARMACOLOGICAL RESEARCH, 2000, 42 (04) :373-381
[3]  
Eyal S, 2002, ELECTROPHORESIS, V23, P2653, DOI 10.1002/1522-2683(200208)23:16<2653::AID-ELPS2653>3.0.CO
[4]  
2-H
[5]   A microfabricated fluorescence-activated cell sorter [J].
Fu, AY ;
Spence, C ;
Scherer, A ;
Arnold, FH ;
Quake, SR .
NATURE BIOTECHNOLOGY, 1999, 17 (11) :1109-1111
[6]   CD28/B7 system of T cell costimulation [J].
Lenschow, DJ ;
Walunas, TL ;
Bluestone, JA .
ANNUAL REVIEW OF IMMUNOLOGY, 1996, 14 :233-258
[7]   Transport, manipulation, and reaction of biological cells on-chip using electrokinetic effects [J].
Li, PCH ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1564-1568
[8]  
Melrose J, 1998, J IMMUNOL, V161, P2457
[9]  
Preckel T., 2002, JALA, V7, P85
[10]   From micro- to nanofabrication with soft materials [J].
Quake, SR ;
Scherer, A .
SCIENCE, 2000, 290 (5496) :1536-1540