Nanoscale affinity chip interface for coupling inhibition SPR immunosensor screening with nano-LC TOF MS

被引:39
作者
Marchesini, G. R. [1 ]
Buijs, J. [2 ]
Haasnoot, W. [1 ]
Hooijerink, D. [1 ]
Jansson, O. [2 ]
Nielen, M. W. F. [1 ,3 ]
机构
[1] RIKILT Inst Food Safety, NL-6700 AE Wageningen, Netherlands
[2] GE Healthcare Europe AB, Uppsala 75125, Sweden
[3] Wageningen Univ, Organ Chem Lab, NL-6703 HB Wageningen, Netherlands
关键词
D O I
10.1021/ac071564p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The on-line nanoscale coupling of a, surface plasmon resonance (SPR)-based inhibition biosensor immunoassay (MU) for the screening of low molecular weight molecules with nano-liquid-chromatography electrospray ionization time-of-flight mass spectrometry (nano-LC ESI TOF MS) for identification is described. The interface is based on a reusable recovery chip (RC) that contains a nanoscale biosorbent composed of a hydrogel layer modified with antibodies raised against the analyte featuring the unique possibility of performance characterization using the SPR biosensor. Various hydrogel chemistries were evaluated, and the standard Biacore CM5 chip showed the highest capture capacity in combination with affinity-purified polyclonal antibodies. The procedure has four stages: the samples are prepared (1) and screened using a screening chip (SC) in the iBIA (2). Suspected noncompliant samples as being noncompliant are reinjected over the RC, and the analyte is captured at sub-nanogram level (3). The captured analyte is released, and the eluate is analyzed with nano-ILC ESI TOF MS via a loop-type interface (4). The coupling of the technologies proved effective for screening enrofloxacin, a model compound, in incurred chicken muscle samples followed by identity confirmation in suspected noncompliant samples. Ciprofloxacin, a known metabolite of enrofloxacin, was identified as well in incurred chicken samples. This demonstrates the potential of the technologies coupled by means of a RC for the rapid screening and identification of known as well as unknown compounds. Finally, we demonstrate the feasibility of combining the two biosensor chips (SC and RC) with a robust chip-based nano-LC chip TOF MS system, thus providing a robust alternative triple-chip system.
引用
收藏
页码:1159 / 1168
页数:10
相关论文
共 31 条
[21]   Analysis of native proteins from biological fluids by biomolecular interaction analysis mass spectrometry (BIA/MS): exploring the limit of detection, identification of non-specific binding and detection of multi-protein complexes [J].
Nedelkov, D ;
Nelson, RW .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :1071-1078
[22]   Development of surface plasmon resonance mass spectrometry array platform [J].
Nedelkov, Dobrin .
ANALYTICAL CHEMISTRY, 2007, 79 (15) :5987-5990
[23]   Surface plasmon resonance biomolecular interaction analysis mass spectrometry .1. Chip-based analysis [J].
Nelson, RW ;
Krone, JR ;
Jansson, O .
ANALYTICAL CHEMISTRY, 1997, 69 (21) :4363-4368
[24]  
PIKKEMAAT MG, IN PRESS FOOD ADDIT
[25]   Survey of the year 2005 commercial optical biosensor literature [J].
Rich, Rebecca L. ;
Myszka, David G. .
JOURNAL OF MOLECULAR RECOGNITION, 2006, 19 (06) :478-534
[26]   Kinetic analysis of estrogen receptor/ligand interactions [J].
Rich, RL ;
Hoth, LR ;
Geoghegan, KF ;
Brown, TA ;
LeMotte, PK ;
Simons, SP ;
Hensley, P ;
Myszka, DG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2002, 99 (13) :8562-8567
[27]   QUANTITATIVE-DETERMINATION OF SURFACE CONCENTRATION OF PROTEIN WITH SURFACE-PLASMON RESONANCE USING RADIOLABELED PROTEINS [J].
STENBERG, E ;
PERSSON, B ;
ROOS, H ;
URBANICZKY, C .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1991, 143 (02) :513-526
[28]   Probing the functional heterogeneity of surface binding sites by analysis of experimental binding traces and the effect of mass transport limitation [J].
Svitel, Juraj ;
Boukari, Hacene ;
Van Ryk, Donald ;
Willson, Richard C. ;
Schuck, Peter .
BIOPHYSICAL JOURNAL, 2007, 92 (05) :1742-1758
[29]   Microfluidic chip for peptide analysis with an integrated HPLC column, sample enrichment column, and nanoelectrospray tip [J].
Yin, NF ;
Killeen, K ;
Brennen, R ;
Sobek, D ;
Werlich, M ;
van de Goor, TV .
ANALYTICAL CHEMISTRY, 2005, 77 (02) :527-533
[30]   Real-time two-wavelength surface plasmon resonance as a tool for the vertical resolution of binding processes in biosensing hydrogels [J].
Zacher, T ;
Wischerhoff, E .
LANGMUIR, 2002, 18 (05) :1748-1759