Achievements and perspectives of top-down proteomics

被引:59
作者
Armirotti, Andrea [1 ]
Damonte, Gianluca [2 ,3 ]
机构
[1] Adv Biotechnol Ctr, I-16132 Genoa, Italy
[2] Univ Genoa, Dept Expt Med, Genoa, Italy
[3] Ctr Excellence Biomed Res, Genoa, Italy
关键词
ESI; LC-MS; MALDI; Phosphorylation; Technology; Top-down; ELECTRON-CAPTURE DISSOCIATION; TANDEM MASS-SPECTROMETRY; COLLISIONALLY ACTIVATED DISSOCIATION; PROTEIN IDENTIFICATION TECHNOLOGY; CHROMATOGRAPHIC TIME-SCALE; MULTIPLY-CHARGED IONS; IN-SOURCE DECAY; INTACT PROTEINS; BOTTOM-UP; REVERSED-PHASE;
D O I
10.1002/pmic.201000245
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the last years, top-down (TD) MS has gained a remarkable space in proteomics, rapidly trespassing the limit between a promising approach and a solid, established technique. Several research groups worldwide have implemented TD analysis in their routine work on proteomics, deriving structural information on proteins with the level of accuracy that is impossible to achieve with classical bottom-up approaches. Complete maps of PTMs and assessment of single aminoacid polymorphisms are only a few of the results that can be obtained with this technique. Despite some existing technical and economical limitations, TD analysis is at present the most powerful instrument for MS-based proteomics and its implementation in routine workflow is a rapidly approaching turning point in proteomics. In this review article, the state-of-the-art of TD approach is described along with its major advantages and drawbacks and the most recent trends in TD analysis are discussed. References for all the covered topics are reported in the text, with the aim to support both newcomers and mass spectrometrists already introduced to TD proteomics.
引用
收藏
页码:3566 / 3576
页数:11
相关论文
共 77 条
[1]   How to discriminate between leucine and isoleucine by low energy ESI-TRAP MSn [J].
Armirotti, Andrea ;
Millo, Enrico ;
Damonte, Gianluca .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (01) :57-63
[2]   Bottom-Up Proteomics [J].
Armirotti, Andrea .
CURRENT ANALYTICAL CHEMISTRY, 2009, 5 (02) :116-130
[3]   Top-down proteomics with a quadrupole time-of-flight mass spectrometer and collision-induced dissociation [J].
Armirotti, Andrea ;
Benatti, Umberto ;
Damonte, Gianluca .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (05) :661-666
[4]   Evaluation of a cleavable stable isotope labeled synthetic peptide for absolute protein quantification using LC-MS/MS [J].
Barnidge, DR ;
Hall, GD ;
Stocker, JL ;
Muddiman, DC .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (03) :658-661
[5]   Mass Spectrometry Bioinformatics: Tools for Navigating the Proteomics Landscape [J].
Blackburn, Kevin ;
Goshe, Michael B. .
CURRENT ANALYTICAL CHEMISTRY, 2009, 5 (02) :131-143
[6]   Proteomics by FTICR mass spectrometry: Top down and bottom up [J].
Bogdanov, B ;
Smith, RD .
MASS SPECTROMETRY REVIEWS, 2005, 24 (02) :168-200
[7]   Combined top-down and bottom-up identifies a phosphorylation proteins that contributes to proteomics site in stem-loop-binding high-affinity RNA binding [J].
Borchers, CH ;
Thapar, R ;
Petrotchenko, EV ;
Torres, MP ;
Speir, JP ;
Easterling, M ;
Dominski, Z ;
Marzluff, WF .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (09) :3094-3099
[8]   Detailed unfolding and folding of gaseous ubiquitin ions characterized by electron capture dissociation [J].
Breuker, K ;
Oh, HB ;
Horn, DM ;
Cerda, BA ;
McLafferty, FW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2002, 124 (22) :6407-6420
[9]   Analysis of intact proteins on a chromatographic time scale by electron transfer dissociation tandem mass spectrometry [J].
Chi, An ;
Bai, Dina L. ;
Geer, Lewis Y. ;
Shabanowitz, Jeffrey ;
Hunt, Donald F. .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 259 (1-3) :197-203
[10]   Mass spectrometry of whole proteins eluted from sodium dodecyl sulfate-polyacrylamide gel electrophoresis gels [J].
Cohen, SL ;
Chait, BT .
ANALYTICAL BIOCHEMISTRY, 1997, 247 (02) :257-267