Proteomics by FTICR mass spectrometry: Top down and bottom up

被引:330
作者
Bogdanov, B
Smith, RD
机构
[1] Pacific NW Natl Lab, Div Biol Sci, Richland, WA 99352 USA
[2] Pacific NW Natl Lab, Environm Mol Sci Lab, Richland, WA 99352 USA
关键词
FTICR; peptides; proteins; fragmentation; chromatography;
D O I
10.1002/mas.20015
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This review provides a broad overview of recent Fourier transform ion cyclotron resonance (FTICR) applications and technological developments relevant to the field of proteomics. Both the "bottom up" (peptide level) and "top down" (intact protein level) approaches are discussed and illustrated with examples. "Bottom up" topics include peptide fragmentation, the accurate mass and time (AMT) tag approach and dynamic range extension technology, aspects of quantitative proteomics measurements, post-translational modifications, and developments in FTICR operation software focused on peptide and protein identification. Topics related to the "top down " approach include various aspects of high mass measurements, protein tandem mass spectrometry, methods for the study of protein conformations, and protein complexes as well as advanced technologies that may become of practical utility in the coming years. Finally, early examples of the integration of both FTICR approaches to biomedical proteomics applications are presented, along with an outlook for future directions. (C) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:168 / 200
页数:33
相关论文
共 148 条
  • [1] Baykut G, 2000, RAPID COMMUN MASS SP, V14, P1238, DOI 10.1002/1097-0231(20000730)14:14<1238::AID-RCM17>3.0.CO
  • [2] 2-H
  • [3] Zeptomole-sensitivity electrospray ionization - Fourier transform ion cyclotron resonance mass spectrometry of proteins
    Belov, ME
    Gorshkov, MV
    Udseth, HR
    Anderson, GA
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (10) : 2271 - 2279
  • [4] Initial implementation, of external accumulation liquid chromatography/electrospray ionization Fourier transform ion cyclotron resonance with automated gain control
    Belov, ME
    Rakov, VS
    Nikolaev, EN
    Goshe, MB
    Anderson, GA
    Smith, RD
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (07) : 627 - 636
  • [5] Higher-resolution data-dependent selective external ion accumulation for capillary LC-FTICR
    Belov, ME
    Anderson, GA
    Smith, RD
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 218 (03) : 265 - 279
  • [6] Dynamic range expansion applied to mass spectrometry based on data-dependent selective ion ejection in capillary liquid chromatography Fourier transform ion cyclotron resonance for enhanced proteome characterization
    Belov, ME
    Anderson, GA
    Angell, NH
    Shen, YF
    Tolic, N
    Udseth, HR
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (21) : 5052 - 5060
  • [7] Controlled ion fragmentation in a 2-D quadrupole ion trap for external ion accumulation in ESI FTICR mass spectrometry
    Belov, ME
    Gorshkov, MV
    Udseth, HR
    Smith, RD
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (12) : 1312 - 1319
  • [8] Automated gain control and internal calibration with external ion accumulation capillary liquid chromatography-electrospray ionization-fourier transform ion cyclotron resonance
    Belov, ME
    Zhang, R
    Strittmatter, EF
    Prior, DC
    Tang, K
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (16) : 4195 - 4205
  • [9] High-throughput global peptide proteomic analysis by combining stable isotope amino acid labeling and data-dependent multiplexed-MS/MS
    Berger, SJ
    Lee, SW
    Anderson, GA
    Pasa-Tolic, L
    Tolic, N
    Shen, YF
    Zhao, R
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (19) : 4994 - 5000
  • [10] Peptide mapping of proteins in human body fluids using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
    Bergquist, J
    Palmblad, M
    Wetterhall, M
    Håkansson, P
    Markides, KE
    [J]. MASS SPECTROMETRY REVIEWS, 2002, 21 (01) : 2 - 15