Inhalation challenge testing of latex-sensitive health care workers and the effectiveness of laminar flow HEPA-filtered helmets in reducing rhinoconjunctival and asthmatic reactions

被引:40
作者
Laoprasert, N
Swanson, MC
Jones, RT
Schroeder, DR
Yunginger, JW
机构
[1] Mayo Clin & Mayo Fdn, Allerg Dis Res Lab, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Dept Hlth Sci Res, Biostat Sect, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Mayo Grad Sch Med, Rochester, MN 55905 USA
[4] Mayo Clin & Mayo Fdn, Dept Pediat & Adolescent Med, Rochester, MN 55905 USA
关键词
latex allergy; inhalation challenge tests; latex aeroallergens; health care workers;
D O I
10.1016/S0091-6749(98)70338-0
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: There are few data relating latex aeroallergen concentrations to biologic responses in latex-sensitized persons. Objectives: We sought to investigate acceptable latex aeroallergen concentrations below which latex-sensitive health care workers do not experience symptoms and to study the effect of high-efficiency particle arrest (HEPA)-filtered laminar flow helmets in preventing latex-induced symptoms. Methods: Under challenge chamber conditions, latex-sensitive health care workers underwent 7 sequential inhalation challenge tests by donning and discarding either vinyl gloves (challenge 1), low latex-allergen powder-free gloves (challenge 2), or high latex-allergen powdered gloves (challenges 3 to 7) for up to 1 hour. Volunteers wore a laminar flow helmet during all challenges; HEPA biters in the helmet were in place only during challenges 3 and 4. Flow-volume loops, symptom scores, and latex aeroallergen concentrations were measured before and during each test. Results: At 60 minutes, latex aeroallergen concentrations during challenges 3 to 7 (mean, 7600 ng/m(3); range, 93 to 54,000 ng/m3) were significantly higher than during challenges 1 or 2 (mean, 65 ng/m(3); range, nondetectable to 100 ng/m(3)) (P < .001). During challenges 5 and 6, mean maximum percent falls in FEV1 (-16% and -11%, respectively) were significantly greater compared with those measured during challenges 3 and 4 (-3% and -1%, respectively) (P = .03). Mean maximum change from baseline symptom scores during challenges 5 and 6 was significantly higher than that during challenges 3 and 4 (P = .006), During challenges with high latex-allergen gloves, 4 volunteers had reproducible FEV1 falls of 20% or greater at cumulative inhaled latex aeroallergen doses ranging from less than 100 ng to 1500 ng. Conclusion: The laminar flow helmets were effective in reducing latex-induced symptoms. Only 1 volunteer exhibited a fall in FEV1 of 20% or greater after a cumulative inhaled latex aeroallergen dose of less than 100 ng, and no volunteer showed a decline in FEV1 after exposure to powder-free low allergen gloves.
引用
收藏
页码:998 / 1004
页数:7
相关论文
共 12 条
[2]   Can a threshold limit value for natural rubber latex airborne allergens be defined? [J].
Baur, X ;
Chen, ZP ;
Allmers, H .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1998, 101 (01) :24-27
[3]   WORK-RELATED LATE ASTHMATIC RESPONSE INDUCED BY LATEX ALLERGY [J].
BRUGNAMI, G ;
MARABINI, A ;
SIRACUSA, A ;
ABBRITTI, G .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1995, 96 (04) :457-464
[4]   A prospective, controlled study showing that rubber gloves are the major contributor to latex aeroallergen levels in the operating room [J].
Heilman, DK ;
Jones, RT ;
Swanson, MC ;
Yunginger, JW .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1996, 98 (02) :325-330
[5]   CROSS-SECTIONAL FOLLOW-UP OF A FLU-LIKE RESPIRATORY ILLNESS AMONG FIBERGLASS MANUFACTURING EMPLOYEES - ENDOTOXIN EXPOSURE ASSOCIATED WITH 2 DISTINCT SEQUELAE [J].
MILTON, DK ;
AMSEL, J ;
REED, CE ;
ENRIGHT, PL ;
BROWN, LR ;
AUGHENBAUGH, GL ;
MOREY, PR .
AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1995, 28 (04) :469-488
[6]   BRONCHIAL PROVOCATION TESTING IN THE DIAGNOSIS OF OCCUPATIONAL ASTHMA DUE TO LATEX SURGICAL GLOVES [J].
PISATI, G ;
BARUFFINI, A ;
BERNABEO, F ;
STANIZZI, R .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (02) :332-336
[7]   QUANTIFICATION OF OCCUPATIONAL LATEX AEROALLERGENS IN A MEDICAL-CENTER [J].
SWANSON, MC ;
BUBAK, ME ;
HUNT, LW ;
YUNGINGER, JW ;
WARNER, MA ;
REED, CE .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1994, 94 (03) :445-451
[8]   CONTROL OF AIRBORNE LATEX BY USE OF POWDER-FREE LATEX GLOVES [J].
TARLO, SM ;
SUSSMAN, G ;
CONTALA, A ;
SWANSON, MC .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1994, 93 (06) :985-989
[9]  
US Department Health and Human Services, 1987, GUID VAL LIM AM LYS
[10]  
VANDENPLAS O, 1995, AM J RESP CRIT CARE, V151, P887