An ion exchange liquid chromatography/mass spectrometry method for the determination of reduced and oxidized glutathione and glutathione conjugates in hepatocytes

被引:65
作者
Loughlin, AF [1 ]
Skiles, GL [1 ]
Alberts, DW [1 ]
Schaefer, WH [1 ]
机构
[1] Merck Res Labs, Dept Safety Assessment, Biochem & Invest Toxicol, W Point, PA 19486 USA
关键词
quinone moiety; GSH-menadione conjugate; selected ion monitoring (SIM);
D O I
10.1016/S0731-7085(01)00402-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rugged LC-MS/MS method was developed to quantify reduced and oxidized glutathione (GSH and GSSG, respectively) in rat hepatocytes. In addition, GSH conjugates can be detected, characterized and measured in the same analysis. Samples were treated with acetonitrile and iodoacetic acid to precipitate proteins and trap free GSH, respectively. These highly polar analytes were separated by ion exchange chromatography using conditions that were developed to be amenable to electrospray ionization and provide baseline chromatographic resolution. A solvent gradient with a total run time of 13 min was used to elute the analytes, as well as any highly retained components in the samples that would otherwise accumulate on the HPLC column and degrade the chromatography. The analytes were detected using either selected ion monitoring (SIM) using an ion trap mass spectrometer or selected reaction monitoring (SRM) using a triple quadrupole mass spectrometer, The ranges for quantification of GSH and GSSG using an ion trap were 0.651-488 muM and 0.817-327 muM, respectively. Using SRM with the triple quadrupole instrument, the ranges of quantification for GSH and GSSG were 0.163-163 muM and 0.0816-81.6 muM, respectively. The accuracy and precision for both methods were within 15%. The utility of the method was demonstrated by treating rat hepatocytes with model compounds menadione and precocene I. Menadione, which contains a quinone moiety that undergoes redox cycling and induces concentration- and time-dependent oxidative stress in hepatocytes, resulted in decreased GSH concentrations with concomitant increase in concentrations of GSSG, as well as a GSH-menadione conjugate. When hepatocytes were incubated with precocene I, a time-dependent decrease in GSH concentrations was observed with concomitant increase in a GSH-precocene conjugate. GSSG concentrations did not increase in the presence of precocene I, consistent with its lack of redox activity. This analytical method has general utility for simultaneously investigating the potential of test compounds to induce both oxidative stress from redox cycling in vitro and the formation of GSH conjugates. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:131 / 142
页数:12
相关论文
共 29 条
[1]   MASS-SPECTROMETRY IN THE ANALYSIS OF GLUTATHIONE CONJUGATES [J].
BAILLIE, TA ;
DAVIS, MR .
BIOLOGICAL MASS SPECTROMETRY, 1993, 22 (06) :319-325
[2]   FORMATION AND REDUCTION OF GLUTATHIONE-PROTEIN MIXED DISULFIDES DURING OXIDATIVE STRESS - A STUDY WITH ISOLATED HEPATOCYTES AND MENADIONE (2-METHYL-1,4-NAPHTHOQUINONE) [J].
BELLOMO, G ;
MIRABELLI, F ;
DIMONTE, D ;
RICHELMI, P ;
THOR, H ;
ORRENIUS, C ;
ORRENIUS, S .
BIOCHEMICAL PHARMACOLOGY, 1987, 36 (08) :1313-1320
[3]  
COVEY TR, 1986, ANAL CHEM, V58, P1451
[4]   ALTERATIONS IN INTRACELLULAR THIOL HOMEOSTASIS DURING THE METABOLISM OF MENADIONE BY ISOLATED RAT HEPATOCYTES [J].
DIMONTE, D ;
ROSS, D ;
BELLOMO, G ;
EKLOW, L ;
ORRENIUS, S .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1984, 235 (02) :334-342
[5]  
FARISS MW, 1987, METHOD ENZYMOL, V143, P101
[6]   A comparison between different methods for the determination of reduced and oxidized glutathione in mammalian tissues [J].
Floreani, M ;
Petrone, M ;
Debetto, P ;
Palatini, P .
FREE RADICAL RESEARCH, 1997, 26 (05) :449-455
[7]   QUANTITATIVE-ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION MASS-SPECTROMETRY - THE DETERMINATION OF THE RENIN INHIBITOR CP-80,794 IN HUMAN SERUM [J].
FOUDA, H ;
NOCERINI, M ;
SCHNEIDER, R ;
GEDUTIS, C .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (02) :164-167
[8]   DETERMINATION OF L-365,260, A NEW CHOLECYSTOKININ RECEPTOR (CCK-B) ANTAGONIST, IN PLASMA BY LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
GILBERT, JD ;
HAND, EL ;
YUAN, AS ;
OLAH, TV ;
COVEY, TR .
BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (02) :63-68
[9]   DETERMINATION OF GLUTATHIONE IN BIOLOGICAL SAMPLES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
GOTTI, R ;
ANDRISANO, V ;
GATTI, R ;
CAVRINI, V ;
CANDELETTI, S .
BIOMEDICAL CHROMATOGRAPHY, 1994, 8 (06) :306-308
[10]   2-(4-N-MALEIMIDOPHENYL)-6-METHOXYBENZOFURAN - A SUPERIOR DERIVATIZING AGENT FOR FLUOROMETRIC-DETERMINATION OF ALIPHATIC THIOLS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HAJYEHIA, AI ;
BENET, LZ .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 666 (01) :45-53